Product Model

CLV612-C0000

In Stock
Last updated: 2025/4/19
sick CLV612-C0000

Selling Points

  • 1High-speed scanning with frequencies up to 1,000 Hz.
  • 2Flexible CAN bus connectivity for seamless integration.
  • 3Robust IP65 enclosure for harsh environments.
  • 4Reliable reading of damaged, dirty, and partially covered barcodes.
  • 5Easy configuration with SOPAS ET configuration software.
Product Details
CLV612-C0000
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Version
Short Range
Connection type
Cable
Reading field
Front
Sensor type
Line scanner
Optical focus
Fixed focus
Light source
Light spot, laser, Visible, Red, 655 nm
Laser class
2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014)
Aperture angle
≤ 50°
Reading distance
43 mm ... 93 mm
Scanning frequency
400 Hz ... 1,000 Hz
Code resolution
0.1 mm ... 0.2 mm
Connection type
1 x 15-pin D-Sub HD male connector (0.9 m)
Supply voltage
10 V DC ... 30 V DC
Power consumption
2.8 W
Housing material
Aluminum die cast
Housing color
Light blue (RAL 5012)
Window material
Glass
Enclosure rating
IP65 (DIN 40 050)
Protection class
III (VDE 0106/IEC 1010-1)
Weight
265 g, with connecting cable
Dimensions (L x W x H)
61 mm x 66 mm x 38 mm
MTBF
100,000 h
MTTF
40,000 h (Laser diode)
Readable code structures
1D codes
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode
Code printing process
Label (printed codes)
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 10 (Standard decoder)#!#1 ... 6 (SMART620)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
1,500#!#500 (for multiplexer function in CAN operation)
No. of multiple readings
1 ... 99
Serial_Function
Data interface (read result output), Service interface
Serial_Data transmission rate
2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud
CAN_Function
SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server)
CAN_Data transmission rate
20 kbit/s ... 1 Mbit/s
Digital inputs
4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)
Digital outputs
4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420)
Reading pulse
Digital inputs, non-powered, serial interface, auto pulse, CAN
Optical indicators
1 RGB LED (multifunctional)
Acoustic indicators
Beeper/buzzer (can be switched off, can be allocated as a result indication function)
Configuration software
SOPAS ET
Items supplied
Single scanner

Specifications may be subject to change without notice