Product Model

CLV620-1831S01

In Stock
Last updated: 2025/4/19
sick CLV620-1831S01

Selling Points

  • 1Ethernet Connectivity: Seamlessly integrate with Ethernet for efficient data transmission.
  • 2IP69K Enclosure Rating: Ensure maximum resistance to harsh environments with an IP69K housing.
  • 3High Reading Accuracy: Achieve reliable reading of 1D codes, including damaged or dirty barcodes.
  • 4Flexible Interface Options: Support multiple interfaces such as PROFINET, EtherNet/IP™, EtherCAT, Serial, CAN, CANopen, and PROFIBUS DP.
  • 5Compact Design: Optimize space with a compact design suitable for various industrial applications.
Product Details
CLV620-1831S01
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Version
Mid Range
Connection type
Ethernet
Reading field
Front
Sensor type
Raster scanner
Optical focus
Fixed focus
Light source
Light spot, laser, Visible, Red, 655 nm
Laser class
2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014)
Aperture angle
≤ 50°
Reading distance
63 mm ... 347 mm
Scanning frequency
400 Hz ... 1,200 Hz
Code resolution
0.2 mm ... 1 mm
Raster height, number of lines, at distance
15 mm, 8, 200 mm
Connection type
2 x M12 cylindrical connectors (1 x 17-pin male connector, 4-pin female connector)
Supply voltage
10 V DC ... 30 V DC
Power consumption
4.5 W
Housing material
Stainless steel
Housing color
Stainless steel (unpainted)
Window material
Plastic
Enclosure rating
IP69K (DIN 40 050, part 9)
Protection class
III (VDE 0106/IEC 1010-1)
Weight
+ 854 g, without connecting cable
Dimensions (L x W x H)
85 mm x 154 mm x 84 mm
MTBF
100,000 h
MTTF
40,000 h (Laser diode)
Readable code structures
1D codes
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey
Code printing process
Label (printed codes)
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 20 (Standard decoder)#!#1 ... 6 (SMART620)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
1,500#!#500 (for multiplexer function in CAN operation)
No. of multiple readings
1 ... 99
Ethernet_Function
Data interface (read result output), Service interface
Ethernet_Data transmission rate
10/100 MBit/s
PROFINET_Function
PROFINET Single Port, PROFINET Dual Port (optional via external connection module CDF600-2)
PROFINET_Data transmission rate
10/100 MBit/s
EtherNet/IP™_Data transmission rate
10/100 MBit/s
EtherCAT_Type of fieldbus integration
Optional over external fieldbus module CDF600
Serial_Function
Data interface (read result output), Service interface
Serial_Data transmission rate
2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
CAN_Function
SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server)
CAN_Data transmission rate
20 kbit/s ... 1 Mbit/s
CANopen_Data transmission rate
20 kbit/s ... 1 Mbit/s
PROFIBUS DP_Type of fieldbus integration
Optional over external fieldbus module CDF600-2
Digital inputs
4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 in CDB650)
Digital outputs
4 (“Result 1”, “Result 2”, 2 via optional CMC600 parameter memory in CDB650)
Reading pulse
Digital inputs, serial interface, auto pulse, CAN
Configuration software
SOPAS ET

Specifications may be subject to change without notice