Product Model
CLV630-1120F0

Selling Points
- 1Long-Range Reading: Reads barcodes up to 735 mm with high accuracy.
- 2Ethernet Connectivity: Supports Ethernet, PROFINET, EtherNet/IP™, and other fieldbus interfaces.
- 3IP65 Enclosure Rating: Durable and resistant to harsh environments, including cold storage.
- 4Fixed Focus: Ensures consistent reading performance with a fixed focus optical system.
- 5Heating Capability: Operates reliably in deep-freeze environments down to –35 °C with surface-mounted heating.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Version | Long Range | Connection type | Ethernet |
Reading field | Front | Sensor type | Raster scanner |
Optical focus | Fixed focus | Light source | Light spot, laser, Visible, Red, 655 nm |
Light spot | Circular | Laser class | 2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014) |
Aperture angle | ≤ 50° | Reading distance | 60 mm ... 735 mm |
Scanning frequency | 400 Hz ... 1,200 Hz | Code resolution | 0.35 mm ... 1 mm |
Raster height, number of lines, at distance | 15 mm, 8, 200 mm | Heating | ✔ |
Cold storage applications | ✔ | Connection type | 2 x M12 cylindrical connectors (12-pin male connector, 4-pin female connector) on swivel connector#!#1 x cable, open-ended, 3-wire (2 m) |
Supply voltage | ≤ 24 V DC, ± 10 % | Power consumption | 40 W |
Housing material | Aluminum die cast | Housing color | Light blue (RAL 5012) |
Window material | Glass | Enclosure rating | IP65 (EN 60529) |
Protection class | III (EN 61140) | Weight | 450 g, without connecting cable |
Dimensions (L x W x H) | 61 mm x 96 mm x 50 mm | MTBF | 100,000 h |
MTTF | 40,000 h (Laser diode) | Readable code structures | 1D codes |
Bar code types | All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey | Code printing process | Label (printed codes) |
Print ratio | 2:1 ... 3:1 | No. of codes per scan | 1 ... 20 (Standard decoder)#!#1 ... 6 (SMART decoder) |
No. of codes per reading interval | 1 ... 50 (auto-discriminating) | No. of characters per reading interval | 5,000#!#500 (for multiplexer function in CAN operation) |
No. of multiple readings | 1 ... 99 | Ethernet_Function | Data interface (read result output), Service interface |
Ethernet_Data transmission rate | 10/100 MBit/s | PROFINET_Function | PROFINET Single Port, PROFINET Dual Port (optional via external connection module CDF600-2) |
PROFINET_Data transmission rate | 10/100 MBit/s | EtherNet/IP™_Data transmission rate | 10/100 MBit/s |
EtherCAT_Type of fieldbus integration | Optional over external fieldbus module CDF600 | Serial_Function | Data interface (read result output), Service interface |
Serial_Data transmission rate | 2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232) | CAN_Function | SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server) |
CAN_Data transmission rate | 20 kbit/s ... 1 Mbit/s | CANopen_Data transmission rate | 20 kbit/s ... 1 Mbit/s |
PROFIBUS DP_Type of fieldbus integration | Optional over external fieldbus module CDF600-2 | Digital inputs | 3 (“Sensor 1”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420) |
Digital outputs | 2 (Via optional CMC600 parameter memory in CDB620/CDM420) | Reading pulse | Digital inputs, non-powered, serial interface, auto pulse, CAN |
Optical indicators | 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs)) | Acoustic indicators | Beeper/buzzer (can be switched off, can be allocated as a result indication function) |
Control elements | 2 buttons (choose and start/stop functions) | Configuration software | SOPAS ET |
Memory card | MicroSD memory card (flash card), optional |
Specifications may be subject to change without notice