Product Model
CLV630-1831S01

Selling Points
- 1Reliable Reading in Harsh Environments: Designed to withstand sub-zero temperatures and wet environments.
- 2Fixed Focus and High Accuracy: Ensures precise reading of challenging codes like DPM codes.
- 3Multiple Communication Interfaces: Supports Ethernet, PROFINET, EtherNet/IP, EtherCAT, Serial, CAN, CANopen, and PROFIBUS DP.
- 4IP65 Enclosure Rating: Durable and resistant to dust and water.
- 5Long Reading Distance: Reads codes up to 735 mm with a code resolution of 0.35 mm to 1 mm.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Version | Long Range | Connection type | Ethernet |
Reading field | Front | Sensor type | Raster scanner |
Optical focus | Fixed focus | Light source | Light spot, laser, Visible, Red, 655 nm |
Light spot | Oval | Laser class | 2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014) |
Aperture angle | ≤ 50° | Reading distance | 60 mm ... 735 mm |
Scanning frequency | 400 Hz ... 1,200 Hz | Code resolution | 0.35 mm ... 1 mm |
Raster height, number of lines, at distance | 15 mm, 8, 200 mm | Connection type | 2 x M12 cylindrical connectors (1 x 17-pin male connector, 4-pin female connector) on swivel connector |
Supply voltage | 18 V DC ... 30 V DC | Power consumption | 5 W |
Housing material | Aluminum die cast | Housing color | Light blue (RAL 5012) |
Window material | Plastic | Enclosure rating | IP65 (EN 60529) |
Protection class | III (EN 61140) | Weight | 250 g, without connecting cable |
Dimensions (L x W x H) | 61 mm x 96 mm x 38 mm | MTBF | 100,000 h |
MTTF | 40,000 h (Laser diode) | Readable code structures | 1D codes |
Bar code types | All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey | Code printing process | Inkjet (directly marked codes) |
Print ratio | 2:1 ... 3:1 | No. of codes per scan | 1 ... 20 (Standard decoder)#!#1 ... 6 (SMART decoder) |
No. of codes per reading interval | 1 ... 50 (auto-discriminating) | No. of characters per reading interval | 5,000#!#500 (for multiplexer function in CAN operation) |
No. of multiple readings | 1 ... 99 | Ethernet_Function | Data interface (read result output), Service interface |
Ethernet_Data transmission rate | 10/100 MBit/s | PROFINET_Function | PROFINET Single Port, PROFINET Dual Port (optional via external connection module CDF600-2) |
PROFINET_Data transmission rate | 10/100 MBit/s | EtherNet/IP™_Data transmission rate | 10/100 MBit/s |
EtherCAT_Type of fieldbus integration | Optional over external fieldbus module CDF600 | Serial_Function | Data interface (read result output), Service interface |
Serial_Data transmission rate | 2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232) | CAN_Function | SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server) |
CAN_Data transmission rate | 20 kbit/s ... 1 Mbit/s | CANopen_Data transmission rate | 20 kbit/s ... 1 Mbit/s |
PROFIBUS DP_Type of fieldbus integration | Optional over external fieldbus module CDF600-2 | Digital inputs | 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420) |
Digital outputs | 4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420) | Reading pulse | Digital inputs, non-powered, serial interface, auto pulse, CAN |
Optical indicators | 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs)) | Acoustic indicators | Beeper/buzzer (can be switched off, can be allocated as a result indication function) |
Control elements | 2 buttons (choose and start/stop functions) | Configuration software | SOPAS ET |
Memory card | MicroSD memory card (flash card), optional |
Specifications may be subject to change without notice