Product Model

CLV640-3000

In Stock
Last updated: 2025/4/19
sick CLV640-3000

Selling Points

  • 1Advanced Raster Scanner Technology: The CLV640-3000 features a raster scanner with dynamic focus control, ensuring high code resolution and accuracy.
  • 2Wide Reading Field: Offers a 105° side reading field with a range of 44 mm to 738 mm, making it versatile for various barcode scanning needs.
  • 3Robust Design: Built with die-cast aluminum housing and an IP65 enclosure rating, it withstands harsh industrial environments.
  • 4Versatile Connectivity: Equipped with a 15-pin D-Sub HD male connector and supports Ethernet, CAN, and PROFINET interfaces.
  • 5Enhanced SMART Technology: Features SMART code reconstruction technology for reading damaged or partially obscured codes, increasing read rates and efficiency.
Product Details
CLV640-3000
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Version
Standard Density
Connection type
Cable
Reading field
Side (105°)
Sensor type
Raster scanner
Optical focus
Dynamic focus control
Light source
Light spot, laser, Visible, Red, 655 nm
Light spot
Circular
Laser class
2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014)
Aperture angle
≤ 50°
Reading distance
44 mm ... 738 mm
Scanning frequency
400 Hz ... 1,200 Hz
Code resolution
0.2 mm ... 1 mm
Raster height, number of lines, at distance
15 mm, 8, 185 mm
Connection type
1 x 15-pin D-Sub HD male connector (0.9 m)
Supply voltage
18 V DC ... 30 V DC
Power consumption
5.5 W
Housing material
Aluminum die cast
Housing color
Light blue (RAL 5012)
Window material
Glass
Enclosure rating
IP65 (EN 60529)
Protection class
III (EN 61140)
Weight
340 g, with connecting cable
Dimensions (L x W x H)
80 mm x 96 mm x 38 mm
MTBF
100,000 h
MTTF
40,000 h (Laser diode)
Readable code structures
1D codes
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey
Code printing process
Label (printed codes)
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 20 (Standard decoder)#!#1 ... 6 (SMART decoder)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
5,000#!#500 (for multiplexer function in CAN operation)
No. of multiple readings
1 ... 99
PROFINET_Type of fieldbus integration
Optional over external fieldbus module CDF600-2
PROFINET_Function
PROFINET Single Port, PROFINET Dual Port
EtherCAT_Type of fieldbus integration
Optional over external fieldbus module CDF600
Serial_Function
Data interface (read result output), Service interface
Serial_Data transmission rate
2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
CAN_Function
SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server)
CAN_Data transmission rate
20 kbit/s ... 1 Mbit/s
CANopen_Data transmission rate
20 kbit/s ... 1 Mbit/s
PROFIBUS DP_Type of fieldbus integration
Optional over external fieldbus module CDF600-2
Digital inputs
4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)
Digital outputs
4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420)
Reading pulse
Digital inputs, non-powered, serial interface, auto pulse, CAN
Optical indicators
6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs))
Acoustic indicators
Beeper/buzzer (can be switched off, can be allocated as a result indication function)
Control elements
2 buttons (choose and start/stop functions)
Configuration software
SOPAS ET
Memory card
MicroSD memory card (flash card), optional
Note on use
For Ethernet connection please use an Ethernet version of CLV6xx