Product Model
CLV642-2000

Selling Points
- 1Reads 1D codes with high accuracy and speed, including Code 39, Code 128, and more.
- 2Ensures extended depth of field for reliable code reading across various distances and angles.
- 3Supports Ethernet TCP/IP, EtherNet/IP, PROFINET, and CAN bus for seamless integration into various systems.
- 4Scans at frequencies up to 1,200 Hz with a code resolution of 0.15 mm to 0.25 mm.
- 5Features an IP65-rated aluminum die-cast housing and operates in temperatures from 0°C to +40°C.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Version | High Density | Connection type | Cable |
Reading field | Side (105°) | Sensor type | Line scanner |
Optical focus | Dynamic focus control | Light source | Light spot, laser, Visible, Red, 655 nm |
Light spot | Circular | Laser class | 2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014) |
Aperture angle | ≤ 50° | Reading distance | 30 mm ... 338 mm |
Scanning frequency | 400 Hz ... 1,200 Hz | Code resolution | 0.15 mm ... 0.25 mm |
Connection type | 1 x 15-pin D-Sub HD male connector (0.9 m) | Supply voltage | 18 V DC ... 30 V DC |
Power consumption | 5.5 W | Housing material | Aluminum die cast |
Housing color | Light blue (RAL 5012) | Window material | Glass |
Enclosure rating | IP65 (EN 60529) | Protection class | III (EN 61140) |
Weight | 340 g, with connecting cable | Dimensions (L x W x H) | 80 mm x 96 mm x 38 mm |
MTBF | 100,000 h | MTTF | 40,000 h (Laser diode) |
Readable code structures | 1D codes | Bar code types | All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey |
Code printing process | Label (printed codes) | Print ratio | 2:1 ... 3:1 |
No. of codes per scan | 1 ... 20 (Standard decoder)#!#1 ... 6 (SMART decoder) | No. of codes per reading interval | 1 ... 50 (auto-discriminating) |
No. of characters per reading interval | 5,000#!#500 (for multiplexer function in CAN operation) | No. of multiple readings | 1 ... 99 |
PROFINET_Type of fieldbus integration | Optional over external fieldbus module CDF600-2 | PROFINET_Function | PROFINET Single Port, PROFINET Dual Port |
EtherCAT_Type of fieldbus integration | Optional over external fieldbus module CDF600 | Serial_Function | Data interface (read result output), Service interface |
Serial_Data transmission rate | 2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232) | CAN_Function | SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server) |
CAN_Data transmission rate | 20 kbit/s ... 1 Mbit/s | CANopen_Data transmission rate | 20 kbit/s ... 1 Mbit/s |
PROFIBUS DP_Type of fieldbus integration | Optional over external fieldbus module CDF600-2 | Digital inputs | 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420) |
Digital outputs | 4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420) | Reading pulse | Digital inputs, non-powered, serial interface, auto pulse, CAN |
Optical indicators | 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs)) | Acoustic indicators | Beeper/buzzer (can be switched off, can be allocated as a result indication function) |
Control elements | 2 buttons (choose and start/stop functions) | Configuration software | SOPAS ET |
Memory card | MicroSD memory card (flash card), optional | Note on use | For Ethernet connection please use an Ethernet version of CLV6xx |
Specifications may be subject to change without notice