Product Model

CLV650-0120F0

In Stock
Last updated: 2025/4/19
sick CLV650-0120F0

Selling Points

  • 1Auto Focus Technology: The CLV650-0120F0 features an integrated auto focus system for precise and accurate barcode reading.
  • 2High Scan Frequency: Achieve maximum throughput with a scanning frequency of up to 1,000 Hz.
  • 3Reliable Reading of Damaged Codes: SMART function ensures reliable reading of even damaged, dirty, or partially covered barcodes.
  • 4Flexible Connection Options: Minimize wiring work with flexible connection via CAN bus and support for various fieldbus connections.
  • 5Durable Design: Built with an aluminum die-cast housing and IP65 enclosure rating for robust performance in challenging environments.
Product Details
CLV650-0120F0
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Version
Standard Density
Connection type
Ethernet
Reading field
Front
Sensor type
Line scanner
Optical focus
Auto focus
Light source
Light spot, laser, Visible, Red, 658 nm
Laser class
2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014)
Aperture angle
≤ 50°
Reading distance
140 mm ... 1,625 mm
Scanning frequency
600 Hz ... 1,000 Hz
Code resolution
0.25 mm ... 1 mm
Heating
Cold storage applications
Connection type
2 x M12 cylindrical connectors (12-pin male connector, 4-pin female connector) on swivel connector#!#1 x cable, open-ended, 3-wire (2 m)
Supply voltage
≤ 24 V DC, ± 10 %
Power consumption
40 W
Housing material
Aluminum die cast
Housing color
Light blue (RAL 5012)
Window material
Glass
Enclosure rating
IP65 (EN 60529)
Protection class
III (EN 61140)
Weight
450 g, without connecting cable
Dimensions (L x W x H)
61 mm x 96 mm x 50 mm
MTBF
100,000 h
MTTF
40,000 h (Laser diode)
Readable code structures
1D codes
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey
Code printing process
Label (printed codes)
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 20 (Standard decoder)#!#1 ... 6 (SMART decoder)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
5,000#!#500 (for multiplexer function in CAN operation)
No. of multiple readings
1 ... 99
Ethernet_Function
Data interface (read result output), Service interface
Ethernet_Data transmission rate
10/100 MBit/s
PROFINET_Function
PROFINET Single Port, PROFINET Dual Port (optional via external connection module CDF600-2)
PROFINET_Data transmission rate
10/100 MBit/s
EtherNet/IP™_Data transmission rate
10/100 MBit/s
EtherCAT_Type of fieldbus integration
Optional over external fieldbus module CDF600
Serial_Function
Data interface (read result output), Service interface
Serial_Data transmission rate
2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
CAN_Function
SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server)
CAN_Data transmission rate
20 kbit/s ... 1 Mbit/s
CANopen_Data transmission rate
20 kbit/s ... 1 Mbit/s
PROFIBUS DP_Type of fieldbus integration
Optional over external fieldbus module CDF600-2
Digital inputs
3 (“Sensor 1”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)
Digital outputs
2 (Via optional CMC600 parameter memory in CDB620/CDM420)
Reading pulse
Digital inputs, non-powered, serial interface, auto pulse, CAN
Optical indicators
6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs))
Acoustic indicators
Beeper/buzzer (can be switched off, can be allocated as a result indication function)
Control elements
2 buttons (choose and start/stop functions)
Configuration software
SOPAS ET
Memory card
MicroSD memory card (flash card), optional

Specifications may be subject to change without notice