Selling Points

  • 1High Accuracy and Reliability: The CLV690-0000 ensures precise barcode reading with a wide reading distance of 500 mm to 2,100 mm.
  • 2Versatile Reading Capabilities: Supports multiple barcode types including 1D codes like Interleaved 2 of 5, Codabar, and Code 128.
  • 3Robust Design: Features an IP65-rated aluminum die-cast housing for durability in harsh environments.
  • 4Advanced Configuration Options: Includes SOPAS ET configuration software and parameter cloning via external modules for customized settings.
  • 5Comprehensive Connectivity: Offers digital inputs, serial interface, and CAN connectivity for seamless integration with industrial systems.
Product Details
CLV690-0000
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Version
Standard Density
Connection type
Depending on the cloning plug used
Reading field
Front
Sensor type
Line scanner
Optical focus
Auto focus (alternative: dynamic focus control)
No. of distance configurations
≤ 8
Focus adjustment time
≤ 20 ms
Focus trigger source
Data interface / Digital inputs
Light source
Light spot, laser, Visible, Red, 660 nm
Laser class
2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014)
Aperture angle
≤ 60°
Reading distance
500 mm ... 2,100 mm
Scanning frequency
400 Hz ... 1,200 Hz
Code resolution
0.3 mm ... 1 mm
Connection type
Depending on the cloning plug used
Supply voltage
18 V DC ... 30 V DC
Power consumption
15 W
Housing material
Aluminum die cast
Housing color
Light blue (RAL 5012)
Window material
Glass
Enclosure rating
IP65 (EN 60529/A1 (2002-02))
Weight
1,500 g
Dimensions (L x W x H)
117 mm x 117 mm x 94 mm
MTBF
100,000 h
MTTF
40,000 h (Laser diode)
Readable code structures
1D codes
Bar code types
Interleaved 2 of 5, all current code types, Codabar, Code 128, Code 39, Code 93, GS1-128 / EAN 128, UPC / GTIN / EAN
Code printing process
Label (printed codes)
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 20 (Standard decoder)#!#1 ... 6 (SMART decoder)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
5,000
No. of multiple readings
1 ... 100
Ethernet_Remark
Only with cloning plug I/O, CAN IN/OUT or CAN Redundant
Ethernet_Function
Data interface (read result output), Service interface
Ethernet_Data transmission rate
10/100 MBit/s
PROFINET_Type of fieldbus integration
Optional over external fieldbus module CDF600-2
PROFINET_Remark
Only with cloning plug I/O, CAN IN/OUT or CAN Redundant
PROFINET_Function
PROFINET Single Port, PROFINET Dual Port
EtherNet/IP™_Remark
Only with cloning plug I/O, CAN IN/OUT or CAN Redundant
EtherNet/IP™_Data transmission rate
10/100 MBit/s
Serial_Remark
Only with cloning plug D-Sub and Ethernet
Serial_Function
Data interface (read result output), AUX (only RS-232)
Serial_Data transmission rate
0.3 kBaud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
CAN_Function
SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server)
CAN_Data transmission rate
20 kbit/s ... 1 Mbit/s
PROFIBUS DP_Type of fieldbus integration
Optional over external fieldbus module CDF600-2
Digital inputs
6 (“Sensor 1” ... “Sensor 6”)
Digital outputs
4 (“Result 1” ... “Result 4”)
Reading pulse
Digital inputs, serial interface, auto pulse, CAN
Optical indicators
6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs))
Control elements
2 buttons
Parameter storage
Integrated in cloning plug
Configuration software
SOPAS ET

Specifications may be subject to change without notice