Product Model

CM30-25NAP-KW1

In Stock
Last updated: 2025/4/30
sick CM30-25NAP-KW1

Selling Points

  • 1Reliable Detection: Detect objects at a long sensing distance up to 25mm with high accuracy.
  • 2Adjustable Sensing Range: Adjust the sensing range from 2 to 16 mm shielded and 4 to 25 mm unshielded for versatile use.
  • 3High EMC Immunity: Ensure reliable operation with best-in-class electromagnetic compatibility, reducing false switching and material loss.
  • 4Easy Installation: Quick and easy adjustment via potentiometer saves installation and setup time.
  • 5Durable Design: IP 67 enclosure rating ensures high shock and vibration resistance, increasing sensor life and reducing maintenance costs.
Product Details
CM30-25NAP-KW1
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Metric
Thread size
M30 x 1.5
Diameter
Ø 30 mm
Sensing range Sn
4 mm ... 25 mm
Safe sensing range Sa
18 mm
Installation type
Non-flush
Switching frequency
10 Hz
Connection type
Cable, 2-wire, 2 m
Output function
NC or NO
Electrical wiring
AC 2-wire
Adjustment_Potentiometer
Sensitivity (11 turns)
Enclosure rating
IP67 (According to EN 60529)
Items supplied
Mounting nut, PA12 plastic (2x)#!#Screwdriver for potentiometer adjustment (1 x)
Supply voltage
20 V AC ... 250 V AC
Ripple
≤ 10 %
Voltage drop
≤ 10 V DC
Current consumption
10 mA
Time delay before availability
≤ 100 ms
Hysteresis
4 % ... 20 %
Reproducibility
≤ 5 %
Temperature drift (of Sr)
± 10 %
EMC
According to EN 60947-5-2
Continuous current Ia
≤ 500 mA
Cable material
PVC
Conductor size
0.5 mm²
Power-up pulse protection
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +80 °C
Housing material
Plastic, PBT
Housing length
75.6 mm
Thread length
50 mm
Tightening torque, max.
≤ 7.5 Nm
Note
The values are reference values which may vary
Metal
1
Water
1
PVC
Approx. 0.4
Oil
Approx. 0.25
Glass
0.6
Ceramics
0.5
Alcohol
0.7
Wood
0.2 ... 0.7
Remark
Associated graphic see "Installation"
A
30 mm
B
60 mm
C
30 mm
D
75 mm
E
14.5 mm#!#In critical distances, the sensor should be tested in the application

Specifications may be subject to change without notice