Product Model

CM30-25NNP-EW1

In Stock
Last updated: 2025/4/19
sick CM30-25NNP-EW1

Selling Points

  • 1Potentiometer allows for precise sensitivity adjustment (11 turns).
  • 2IP68 and IP69K rated for harsh environments and water resistance.
  • 3Detects objects from 4 mm to 25 mm with high accuracy.
  • 4NPN output configuration for easy integration into control systems.
  • 5Made from PBT plastic with a 2-meter cable for reliable operation.
Product Details
CM30-25NNP-EW1
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Metric
Thread size
M30 x 1.5
Diameter
Ø 30 mm
Sensing range Sn
4 mm ... 25 mm
Safe sensing range Sa
19.13 mm
Installation type
Non-flush
Switching frequency
50 Hz
Connection type
Cable, 4-wire, 2 m
Switching output
NPN
Output function
Complementary
Output characteristic
Wire configurable
Electrical wiring
DC 4-wire
Adjustment_Potentiometer
Sensitivity (11 turns)
Enclosure rating
IP683)#!#IP69K
Items supplied
Mounting nut, PA12 plastic (2x)#!#Screwdriver for potentiometer adjustment (1 x)
Supply voltage
10 V DC ... 36 V DC
Ripple
≤ 10 %
Voltage drop
≤ 2 V DC
Current consumption
12 mA
Time delay before availability
≤ 200 ms
Hysteresis
3 % ... 20 %
Reproducibility
≤ 5 %
Temperature drift (of Sr)
± 10 %
EMC
According to EN 60947-5-2
Continuous current Ia
≤ 200 mA
Cable material
PVC
Conductor size
0.34 mm²
Cable diameter
Ø 5.2 mm
Short-circuit protection
Power-up pulse protection
Shock and vibration resistance
According to EN 60068
Ambient operating temperature
–30 °C ... +85 °C
Ambient temperature, storage
–40 °C ... +85 °C
Housing material
Plastic, PBT
Housing length
81 mm
Thread length
45.5 mm
Tightening torque, max.
≤ 7.5 Nm
UL File No.
NRKH.E191603
Note
The values are reference values which may vary
Metal
1
Water
1
PVC
Approx. 0.4
Oil
Approx. 0.25
Glass
0.6
Ceramics
0.5
Alcohol
0.7
Wood
0.2 ... 0.7
Remark
Associated graphic see "Installation"
A
30 mm
B
60 mm
C
30 mm
D
75 mm
E
14.5 mm#!#In critical distances, the sensor should be tested in the application

Specifications may be subject to change without notice