Product Model
CMB18-08BPPEC0SA00

Selling Points
- 1Designed to withstand harsh environments with EN 60068-2-27 shock resistance Ea: 30 g 11 ms; 3 shocks in each direction of the 3 coordinate axes.
- 2Offers a sensing range of 0 mm to 8 mm, ensuring accurate detection of objects and levels.
- 3Equipped with IO-Link V1.1 for efficient communication and parameterization, enabling predictive maintenance and Industry 4.0 applications.
- 4Provides excellent protection against dust and water, making it suitable for various industrial settings.
- 5Facilitates quick installation with a visual adjustment indicator, ensuring precise settings without complex procedures.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Metric | Thread size | M18 x 1 |
Diameter | Ø 18 mm | Sensing range Sn | 0 mm ... 8 mm |
Safe sensing range Sa | 6.12 mm | Installation type | Flush |
Switching frequency | 50 Hz | Connection type | Male connector M12, 4-pin |
Switching output | PNP | Output function | Complementary |
Output characteristic | Wire configurable | Electrical wiring | DC 4-wire |
Adjustment_Potentiometer | Sensitivity (11 turns) | Adjustment_Wire/pin | Sensitivity |
Adjustment_IO-Link | Sensitivity, sensor parameters and Smart Task functions | Enclosure rating | IP67#!#IP682)#!#IP69K |
Special features | Visual adjustment indicator, Smart Task, IO-Link | Pin 2 configuration | External input, Teach-in, switching signal |
Items supplied | Mounting nut, PA12 plastic (2x)#!#Screwdriver for potentiometer adjustment (1 x) | Supply voltage | 10 V DC ... 36 V DC |
Ripple | ≤ 10 % | Voltage drop | ≤ 2.5 V DC |
Current consumption | ≤ 20 mA | Time delay before availability | ≤ 300 ms |
Hysteresis | 3 % ... 20 % | Reproducibility | ≤ 5 % |
Temperature drift (of Sr) | ± 10 % | EMC | EN 61000-4-2 ESD: > 40 kV CD and AD#!#EN 61000-4-3 Radiated RF: 20 V/m#!#EN 61000-4-4 burst: +/- 4 kV / 5 kHz#!#EN 61000-4-5 Surge: Voltage supply > 2 kV with 500 ohm; switching output > 2 kV with 500 ohm#!#EN 61000-4-6 HF: > 20 Vrms#!#EN 61000-4-8 mains frequency magnetic fields: Permanent > 60 A/m, 75,9 µ tesla; briefly > 600 A/m, 759 µ tesla |
Continuous current Ia | ≤ 200 mA | Short-circuit protection | ✔ |
Power-up pulse protection | ✔ | Shock and vibration resistance | EN 60068-2-27 shock resistance Ea: 30 g 11 ms; 3 shocks in each direction of the 3 coordinate axes#!#IEC 60068-2-31 drop test: 2 times from 1 m, 100 times from 0.5 m#!#EN 60068-2-6 vibration resistance Fc: 10 Hz ... 150 Hz, 1 mm / 15 g |
Ambient operating temperature | –30 °C ... +85 °C | Ambient temperature, storage | –40 °C ... +85 °C |
Housing material | Plastic, PBT | Housing length | 85 mm |
Thread length | 55 mm | Tightening torque, max. | ≤ 2.6 Nm |
UL File No. | NRKH.E191603 | Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) | Cycle time | > 5 ms |
Process data length | 4 Byte | Process data structure | Bit 0 = switching signal QL1#!#Bit 1 = switching signal QL2#!#Bit 2 = Sensor switching channel Qint1#!#Bit 3 = Sensor switching channel Qint2#!#Bit 4 = Contamination alarm for switching channel Qint1#!#Bit 5 = Contamination channel for Qint2#!#Bit 6 = Temperature alarm#!#Bit 7 = Short-circuit#!#Bit 16 ... 31 = Analog value (digit value, not linearized) |
Note | The values are reference values which may vary | Metal | 1 |
Water | 1 | PVC | Approx. 0.4 |
Oil | Approx. 0.25 | Glass | 0.6 |
Ceramics | 0.5 | Alcohol | 0.7 |
Wood | 0.2 ... 0.7 | Remark | Associated graphic see "Installation" |
B | 18 mm | C | 18 mm |
D | 24 mm | F | 24 mm |
Smart Task name | Base logics | Logic function | Direct#!#AND#!#OR#!#Window#!#Hysteresis |
Timer function | Deactivated#!#Switch-on delay#!#Off delay#!#ON and OFF delay#!#Impulse (one shot) | Inverter | Yes |
Switching signal_Switching signal QL1 | Switching output | Switching signal_Switching signal QL2 | Switching output |
Specifications may be subject to change without notice