Product Model

GL10-03811S01

In Stock
Last updated: 2025/4/18
sick GL10-03811S01

Selling Points

  • 1High Accuracy and Reliability: The GL10-03811S01 ensures precise detection with a sensing range of up to 15 meters.
  • 2Dual Lens Design: Features a dual lens design for enhanced performance and flexibility.
  • 3Retroreflective Sensing: Utilizes retroreflective sensing technology for accurate detection of reflective surfaces.
  • 4SPDT Relay Output: Provides a switching output relay for easy integration into control systems.
  • 5IP67 Protection: Offers robust IP67 protection against dust and water, ensuring reliable operation in harsh environments.
Product Details
GL10-03811S01
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Functional principle
Photoelectric retro-reflective sensor
Functional principle detail
With minimum distance to reflector (dual lens system)
Dimensions (W x H x D)
20 mm x 50 mm x 51.5 mm
Housing design (light emission)
Rectangular
Sensing range max.
0.08 m ... 15 m1)#!#0.08 m ... 12 m2)
Sensing range
0.15 m ... 12 m1)#!#0.15 m ... 10 m2)
Type of light
Visible red light
Light source
PinPoint LED
Light spot size (distance)
Ø 58 mm (5 m)
Wave length
625 nm
Adjustment
Potentiometer, 270°
Supply voltage UB
12 V DC ... 30 V DC
Ripple
< 5 V
Current consumption
40 mA
Switching output
Relay, SPDT, electrically isolated
Switching load max. (current/voltage)
0.11 A (250 V DC)#!#3 A (30 V DC)#!#3 A (250 V AC)
Response time
≤ 10 ms
Switching frequency
20 Hz
Connection type
Cable, 5-wire, 2 m
Cable material
Plastic, PVC
Conductor cross section
0.25 mm²
Circuit protection
C
Protection class
II
Weight
115 g
Polarisation filter
Interference emission
EN 61000-6-3 (2011-09)
Special device
Housing material
Plastic, ABS/PMMA
Enclosure rating
IP67
Relay switching cycles min.
100.000 cycles (3 A)
Electromagnetic compatibility (EMC)
EN 60947-5-2#!#EN 61000-6-3 (2011-09)
Ambient operating temperature
–30 °C ... +60 °C
Ambient temperature, storage
–40 °C ... +70 °C
UL File No.
NRKH.E348498 & NRKH7.E348498
More standards
UL325

Specifications may be subject to change without notice