Product Model
GRTE18S-P134Z

Selling Points
- 1High Reliability: Built to last with an average service life of 100,000 hours at +25°C.
- 2Versatile Applications: Suitable for various industrial settings, including detection of visible red light and infrared light.
- 3Adjustable Sensitivity: Features a potentiometer for easy adjustment of sensitivity to meet specific detection needs.
- 4Compact Design: Compact size with M12 x 1 connector and threaded mounting hole for easy integration.
- 5LED Status Indicator: Equipped with a bright LED status indicator for clear visual feedback.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Functional principle | Photoelectric proximity sensor | Functional principle detail | Energetic |
Dimensions (W x H x D) | 18 mm x 18 mm x 38.1 mm | Housing design (light emission) | Cylindrical |
Thread diameter (housing) | M18 x 1 | Optical axis | Axial, fully flush |
Sensing range max. | 5 mm ... 550 mm | Sensing range | 10 mm ... 400 mm |
Type of light | Visible red light | Light source | PinPoint LED |
Light spot size (distance) | Ø 9 mm (400 mm) | Wave length | 650 nm |
Adjustment | Potentiometer, 270° | Indication_LED green | Operating indicatorStatic on: power on |
Indication_LED yellow | Status of received light beamStatic on: object presentStatic off: object not present | Supply voltage UB | 10 V DC ... 30 V DC |
Ripple | < 5 V | Current consumption | 30 mA |
Switching output | PNP | Switching mode | Light switching |
Signal voltage PNP HIGH/LOW | V#!#- (≤ 3 V) / approx. 0 V | Output current Imax. | ≤ 100 mA |
Response time | < 1,000 µs | Switching frequency | 500 Hz |
Connection type | Cable, 3-wire, 2 m | Cable material | Plastic, PVC |
Circuit protection | A7)#!#B8)#!#D9) | Protection class | III |
Housing material | Metal, Nickel-plated brass and ABS | Optics material | Plastic, PMMA |
Enclosure rating | IP67 | Items supplied | Fastening nuts (2 x) |
Electromagnetic compatibility (EMC) | EN 60947-5-2 | Ambient operating temperature | –25 °C ... +55 °C |
Ambient temperature, storage | –40 °C ... +70 °C | UL File No. | NRKH.E348498 & NRKH7.E348498 |
Specifications may be subject to change without notice