Product Model
IM12-06BPS-NC1

Selling Points
- 1High-Performance Detection: The IM12-06BPS-NC1 offers precise and reliable detection in industrial settings.
- 2Flush Mounting: Designed for flush mounting, this sensor fits seamlessly into your application.
- 3Normally Closed Output: Provides a normally closed output function for easy integration into your system.
- 4Durable Construction: Built with durable materials to withstand harsh industrial environments.
- 5Easy Installation: Quick and easy installation with M12 connector for efficient setup.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Metric | Thread size | M12 x 1 |
Diameter | Ø 12 mm | Pressure resistance | ≤ 80 bar |
Sensing range Sn | 6 mm | Safe sensing range Sa | 4.86 mm |
Installation type | Flush | Switching frequency | 600 Hz |
Connection type | Male connector M12, 4-pin | Switching output | PNP |
Output function | NO | Electrical wiring | DC 3-wire |
Enclosure rating | IP68, IP69K | Special features | Sensing face made of stainless steel V4A, Resistant to cleaning agents, triple sensing range, Visual adjustment indicator, IO-Link |
Special applications | Hygienic and washdown zones, Difficult application conditions | Items supplied | Mounting nut, V4A stainless steel (2x)#!#Washer, V4A stainless steel, with locking teeth (2x) |
Supply voltage | 10 V DC ... 30 V DC | Ripple | ≤ 20 % |
Voltage drop | ≤ 2 V | Time delay before availability | ≤ 40 ms |
Hysteresis | 1 % ... 15 % | Reproducibility | ≤ 5 % |
Temperature drift (of Sr) | ≤ 10 % | EMC | According to EN 60947-5-2 |
Continuous current Ia | ≤ 200 mA | Short-circuit protection | ✔ |
Power-up pulse protection | ✔ | Shock and vibration resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
Ambient operating temperature | –25 °C ... +85 °C | Housing material | Stainless steel V4A, DIN 1.4404 / AISI 316L |
Sensing face material | Stainless steel V4A, DIN 1.4404 / AISI 316L | Housing length | 60 mm |
Thread length | 41 mm | Tightening torque, max. | ≤ 20 Nm |
Protection class | III | UL File No. | E191603 |
Communication interface | IO-Link V1.0 | Communication Interface detail | COM2 (38,4 kBaud) |
Process data length | 1 Byte | Process data structure | Bit 0 = Sr reached |
Process data structure A | Bit 1 = Sa reached | Note | The values are reference values which may vary |
St37 steel (Fe) | Approx. 1 | Stainless steel (V4A, 316L) | Approx. 0.45 |
Aluminum (Al) | Approx. 1 | Copper (Cu) | Approx. 0.85 |
Brass (Br) | Approx. 1.3 | Remark | Associated graphic see "Installation" |
B | 38 mm | C | 12 mm |
D | 18 mm | F | 60 mm |
Specifications may be subject to change without notice