Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Metric | Housing | Standard design |
Thread size | M18 x 1 | Diameter | Ø 18 mm |
Sensing range Sn | 5 mm | Safe sensing range Sa | 4.05 mm |
Installation type | Flush | Switching frequency | 25 Hz1)#!#50 Hz2) |
Connection type | Cable, 2-wire, 2 m | Output function | NO |
Electrical wiring | AC/DC 2-wire | Enclosure rating | IP67 |
Items supplied | Mounting nut, brass, nickel-plated (2x) | Supply voltage | 20 V AC/DC ... 250 V AC/DC |
Voltage drop | ≤ 6.5 V AC, ≤ 6 V DC | Time delay before availability | ≤ 8 ms |
Hysteresis | 1 % ... 15 % | Reproducibility | ≤ 10 % |
Temperature drift (of Sr) | ± 10 % | EMC | As per EN 55011, class B |
Continuous current Ia | ≤ 350 mA4)#!#≤ 250 mA5)#!#≤ 100 mA6) | Off-state current | ≤ 2.5 mA (AC 250 V)#!#≤ 1.3 mA (AC 110 V)#!#≤ 0.8 mA (DC 24 V) |
Minimum load current | ≥ 5 mA | Short-time withstand current | 2.2 A |
Cable material | PUR | Conductor size | 0.5 mm² |
Short-circuit protection | — | Power-up pulse protection | ✔ |
Shock and vibration resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm | Ambient operating temperature | –25 °C ... +80 °C |
Housing material | Brass, nickel-plated | Sensing face material | Plastic, PBT |
Housing length | 80 mm | Thread length | 58 mm |
Tightening torque, max. | ≤ 35 Nm | Protection class | II |
Rated insulation voltage Ui | 250 V AC | Usage category | AC-1409)#!#DC-1310) |
Contamination rating | 3 | Rated impulse withstand voltage | 4 kV |
Note | The values are reference values which may vary | Stainless steel (V2A, 304) | Approx. 0.8 |
Aluminum (Al) | Approx. 0.45 | Copper (Cu) | Approx. 0.4 |
Remark | Associated graphic see "Installation" | A | 0 mm |
B | 18 mm | C | 18 mm |
D | 15 mm | E | 0 mm |
F | 40 mm |