Product Model
IM30-40NPS-NC1

Selling Points
- 1Robust Non-Flush Design: Suitable for applications requiring precise detection without physical contact.
- 2PNP Switching Output: Ensures reliable operation with a PNP switching output for easy integration.
- 3M30 Housing: Durable and resistant to harsh ambient conditions, ensuring long-lasting performance.
- 4Wide Sensing Range: Detects objects up to 40mm in distance, providing comprehensive coverage.
- 5Easy Installation: Features a straightforward installation process with M30 connector for seamless integration.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Metric | Thread size | M30 x 1.5 |
Diameter | Ø 30 mm | Pressure resistance | ≤ 40 bar |
Sensing range Sn | 40 mm | Safe sensing range Sa | 32.4 mm |
Installation type | Non-flush | Switching frequency | 90 Hz |
Connection type | Male connector M12, 4-pin | Switching output | PNP |
Output function | NO | Electrical wiring | DC 3-wire |
Enclosure rating | IP68, IP69K | Special features | Sensing face made of stainless steel V4A, Resistant to cleaning agents, triple sensing range, Visual adjustment indicator, IO-Link |
Special applications | Hygienic and washdown zones, Difficult application conditions | Items supplied | Mounting nut, V4A stainless steel (2x)#!#Washer, V4A stainless steel, with locking teeth (2x) |
Supply voltage | 10 V DC ... 30 V DC | Ripple | ≤ 20 % |
Voltage drop | ≤ 2 V | Time delay before availability | ≤ 40 ms |
Hysteresis | 1 % ... 15 % | Reproducibility | ≤ 5 % |
Temperature drift (of Sr) | ≤ 10 % | EMC | According to EN 60947-5-2 |
Continuous current Ia | ≤ 200 mA | Short-circuit protection | ✔ |
Power-up pulse protection | ✔ | Shock and vibration resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
Ambient operating temperature | –25 °C ... +85 °C | Housing material | Stainless steel V4A, DIN 1.4404 / AISI 316L |
Sensing face material | Stainless steel V4A, DIN 1.4404 / AISI 316L | Housing length | 63.5 mm |
Thread length | 32 mm | Tightening torque, max. | ≤ 150 Nm |
Protection class | III | UL File No. | E191603 |
Communication interface | IO-Link V1.0 | Communication Interface detail | COM2 (38,4 kBaud) |
Process data length | 1 Byte | Process data structure | Bit 0 = Sr reached |
Process data structure A | Bit 1 = Sa reached | Note | The values are reference values which may vary |
St37 steel (Fe) | Approx. 1 | Aluminum (Al) | Approx. 1 |
Copper (Cu) | Approx. 0.9 | Brass (Br) | Approx. 1.2 |
Remark | Associated graphic see "Installation" | A | 75 mm |
B | 270 mm | C | 30 mm |
D | 120 mm | E | Aluminium: 34 mm, Steel: 18 mm, Brass: 34 mm, Stainless steel: 18 mm |
F | 400 mm |
Specifications may be subject to change without notice