Product Model

IMA18-05BE1ZW2S

In Stock
Last updated: 2025/4/19
sick IMA18-05BE1ZW2S

Selling Points

  • 1High Sensitivity: Detects objects with maximum sensitivity, ensuring accurate detection even at close distances.
  • 2Wide Operating Range: Operates effectively in a broad range of environments, making it versatile for various industrial settings.
  • 3Low Power Consumption: Consumes minimal power, reducing energy costs and extending sensor lifespan.
  • 4Robust Design: Built with durable materials to withstand harsh industrial conditions, ensuring long-term reliability.
  • 5Easy Integration: Simple to integrate into existing systems, minimizing setup time and complexity.
Product Details
IMA18-05BE1ZW2S
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Metric
Thread size
M18 x 1
Diameter
Ø 18 mm
Sensing range Sn
0 mm ... 5 mm
Installation type
Flush
Connection type
Cable, 4-wire, 2 m
Output function
Analog
Repeatability (Tanot constant)
0.3 mm
Repeatability (Taconstant)
± 0.1 mm
Enclosure rating
IP67
Special features
Analog output
Items supplied
Mounting nut, brass, nickel-plated (2x)
Supply voltage
15 V DC ... 30 V DC
Ripple
≤ 20 %
Time delay before availability
≤ 30 ms
Temperature drift (of Sr)
≤ 10 %
No load current
≤ 12 mA
Max. load resistance on QA1
≥ 2 kΩ
Max. load resistance on QA2
400 Ω Ub = 15 V
Output voltage QA1
s = 0 mm: 0 V –0/+0,6 V (23 °C)#!#s = 2,5 mm: +5 V +/-0,6 V (23 °C)#!#s = 5 mm: +10 V +/-0,6 V (23 °C)
Output current QA2
s = 0 mm: 4 mA +/-0.8 mA (23 °C)#!#s = 5 mm: 20 mA +/-0,8 mA (23 °C)
Output voltage
0 V ... 10 V
Output current
4 mA ... 20 mA
Bandwidth
1,000 Hz
Short-circuit protection
Ambient operating temperature
–25 °C ... +70 °C
Housing material
Brass, chromium-plated
Sensing face material
Plastic
Housing length
67 mm
Thread length
52 mm
Remark
Associated graphic see "Installation"
B
18 mm
C
18 mm
D
15 mm
F
40 mm

Specifications may be subject to change without notice