Product Model

IMM04-0B6POVU2S

In Stock
Last updated: 2025/4/19
sick IMM04-0B6POVU2S

Selling Points

  • 1High accuracy and reliability for precise measurements.
  • 2Robust design for durability in harsh industrial environments.
  • 3Easy integration with existing systems for smooth operation.
  • 4Advanced sensing technology for real-time data collection.
  • 5Compatible with a wide range of industrial applications.
Product Details
IMM04-0B6POVU2S
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Metric
Housing
Standard design
Thread size
M4 x 0.5
Diameter
Ø 4 mm
Sensing range Sn
0.6 mm
Safe sensing range Sa
0.486 mm
Installation type
Flush
Switching frequency
5,000 Hz
Connection type
Cable, 3-wire, 2 m
Switching output
PNP
Output function
NC
Electrical wiring
DC 3-wire
Enclosure rating
IP67
Special features
Visual adjustment indicator
Items supplied
Mounting nut, V2A stainless steel (2x)#!#Washer, V2A stainless steel, with locking teeth (2x)#!#Cable flag, Polymatic 50 (1 x)
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 20 %
Voltage drop
≤ 2 V
Time delay before availability
≤ 10 ms
Hysteresis
1 % ... 15 %
Reproducibility
≤ 2.5 %
Temperature drift (of Sr)
≤ 10 %
EMC
EN 60947-5-2
Continuous current Ia
≤ 100 mA
Cable material
PUR
Conductor size
0.08 mm²
Cable diameter
Ø 2.5 mm
Short-circuit protection
Power-up pulse protection
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +70 °C
Housing material
Stainless steel V2A, DIN 1.4305 / AISI 303
Sensing face material
Plastic, LCP
Housing length
22 mm
Thread length
20 mm
Tightening torque, max.
≤ 0.8 Nm
UL File No.
NRKH.E348498
Note
The values are reference values which may vary
St37 steel (Fe)
1
Stainless steel (V2A, 304)
Approx. 0.68
Aluminum (Al)
Approx. 0.51
Copper (Cu)
Approx. 0.38
Brass (Br)
Approx. 0.64
Remark
Associated graphic see "Installation"
B
2 mm
C
4 mm
D
1.8 mm
F
5 mm

Specifications may be subject to change without notice