Product Model
IMS12-04BPSNU2S

Selling Points
- 1High precision distance detection with advanced inductive technology.
- 2Compact design for easy integration into industrial systems.
- 3Reliable operation in harsh environments and demanding conditions.
- 4Wide range of adjustable sensitivity settings for customized performance.
- 5Compatible with various industrial control systems for seamless integration.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Metric | Housing | Standard design |
Thread size | M12 x 1 | Diameter | Ø 12 mm |
Sensing range Sn | 4 mm | Safe sensing range Sa | 3.24 mm |
Installation type | Flush | Switching frequency | 2,000 Hz |
Connection type | Cable, 3-wire, 2 m | Switching output | PNP |
Output function | NO | Electrical wiring | DC 3-wire |
Enclosure rating | IP681)#!#IP69K2) | Special features | Resistant to cleaning agents, Temperature resistance |
Special applications | Mobile machines, Hygienic and washdown zones, Difficult application conditions | Items supplied | Mounting nut, brass, nickel-plated (2x) |
Supply voltage | 7.2 V DC ... 60 V DC | Ripple | ≤ 10 % |
Voltage drop | ≤ 2.5 V | Time delay before availability | 100 ms |
Hysteresis | 3 % ... 20 % | Reproducibility | ≤ 2 % |
Temperature drift (of Sr) | ± 10 % | EMC | Emitted interference and interference immunity in accordance with Motor Insurance Directive ECE-R10 Rev. 5: E1-Type approval#!#Interference immunity in accordance with DIN ISO 11452-2: 100 V/m#!#AM vertical 20 MHz - 800 MHz; AM horizontal 200 MHz - 800 MHz; PM vertical/horizontal 800 MHz - 2.7 GHz#!#Conducted disturbances in accordance with ISO 7637-2 (pulse/severity/failure criterion 12 V/failure criterion 24 V): 1/IV/C/C, 2a/IV/A/A, 2b/IV/C/C, 3a/IV/A/A, 3b/IV/A/A, 4/IV/C/A, 5a/IV/B/B, 5b/IV/B/B#!#EN 61000-4-2 ESD: 4 kV CD / 8 kV AD#!#EN 61000-4-3 HF radiated: 10 V/m#!#EN 61000-4-4 burst: 2 kV#!#EN 61000-4-5 surge: 0,5 kV L-to-L, Ri: 2 Ohm#!#EN 61000-4-6 HF wire-bound: 10 V |
Environmental test | Quick temperature change EN 60068-2-14, Na: TA = –25 °C, TB = 75 °C, t1 = 40 min, t2 = < 10 s, 300 cycles, Delta S#!#≤ 10% | Corrosion test | Salt spray test EN 60068-2-52: severity 5, 4 cycles |
Continuous current Ia | ≤ 200 mA | No load current | ≤ 10 mA |
Cable material | PUR | Conductor size | 0.5 mm² |
Cable diameter | Ø 5 mm | Short-circuit protection | ✔ |
Power-up pulse protection | ✔ | Shock and vibration resistance | Vibration resistance EN 60068-2-6 Fc: 25 g peak (10 Hz ... 2,000 Hz) / –20 °C ... +50 °C#!#Shock resistance EN 60068-2-27 Ea: 100 g 11 ms; 3 shocks in every direction of the 3 coordinate axes / –40 °C ... +85 °C#!#Continuous shock resistance EN 60068-2-29 Eb: 40 g 3 ms rise, 7 ms fall / 5,000 shocks in every direction of the 3 coordinate axes / -20 °C ... +50 °C#!#Broadband noise EN 60068-2-64: 15 g rms (5 Hz ... 2,000 Hz) / 8 hours in every direction of the 3 coordinate axes / –40 °C ... +85 °C |
Ambient operating temperature | –40 °C ... +100 °C | Housing material | Stainless steel V4A, DIN 1.4404 / AISI 316L |
Sensing face material | Plastic, LCP | Housing length | 56 mm |
Thread length | 51 mm | Tightening torque, max. | Typ. 20 Nm |
Protection class | III | UL File No. | E181493 |
Note | The values are reference values which may vary | Stainless steel (V2A, 304) | Approx. 0.65 |
Aluminum (Al) | Approx. 0.35 | Copper (Cu) | Approx. 0.24 |
Brass (Br) | Approx. 0.38 | Remark | Associated graphic see "Installation" |
B | 12 mm | C | 12 mm |
D | 12 mm | F | 32 mm |
Specifications may be subject to change without notice