Product Model

IMS12-08NPSNU2S

In Stock
Last updated: 2025/4/19
sick IMS12-08NPSNU2S

Selling Points

  • 1High Accuracy and Durability: The IMS12-08NPSNU2S offers precise sensing with a maximum sensing range of 8mm and is built with durable stainless steel housing.
  • 2IP69K Rating: Ensures the sensor is resistant to harsh environments, including high-pressure washdowns and extreme temperatures.
  • 3PNP Output: Provides a Normally Open (NO) output function, making it suitable for various industrial applications.
  • 4Wide Operating Voltage: Operates from 7.2 V DC to 60 V DC, offering flexibility in different electrical systems.
  • 5Shock and Vibration Resistance: Designed to withstand mechanical stress with a vibration resistance of up to 25 g peak and shock resistance of up to 100 g.
Product Details
IMS12-08NPSNU2S
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Metric
Housing
Standard design
Thread size
M12 x 1
Diameter
Ø 12 mm
Sensing range Sn
8 mm
Safe sensing range Sa
6.48 mm
Installation type
Non-flush
Switching frequency
2,000 Hz
Connection type
Cable, 3-wire, 2 m
Switching output
PNP
Output function
NO
Electrical wiring
DC 3-wire
Enclosure rating
IP681)#!#IP69K2)
Special features
Resistant to cleaning agents, Temperature resistance
Special applications
Mobile machines, Hygienic and washdown zones, Difficult application conditions
Items supplied
Mounting nut, brass, nickel-plated (2x)
Supply voltage
7.2 V DC ... 60 V DC
Ripple
≤ 10 %
Voltage drop
≤ 2.5 V
Time delay before availability
100 ms
Hysteresis
3 % ... 20 %
Reproducibility
≤ 2 %
Temperature drift (of Sr)
± 10 %
EMC
Emitted interference and interference immunity in accordance with Motor Insurance Directive ECE-R10 Rev. 5: E1-Type approval#!#Interference immunity in accordance with DIN ISO 11452-2: 100 V/m#!#AM vertical 20 MHz - 800 MHz; AM horizontal 200 MHz - 800 MHz; PM vertical/horizontal 800 MHz - 2.7 GHz#!#Conducted disturbances in accordance with ISO 7637-2 (pulse/severity/failure criterion 12 V/failure criterion 24 V): 1/IV/C/C, 2a/IV/A/A, 2b/IV/C/C, 3a/IV/A/A, 3b/IV/A/A, 4/IV/C/A, 5a/IV/B/B, 5b/IV/B/B#!#EN 61000-4-2 ESD: 4 kV CD / 8 kV AD#!#EN 61000-4-3 HF radiated: 10 V/m#!#EN 61000-4-4 burst: 2 kV#!#EN 61000-4-5 surge: 0,5 kV L-to-L, Ri: 2 Ohm#!#EN 61000-4-6 HF wire-bound: 10 V
Environmental test
Quick temperature change EN 60068-2-14, Na: TA = –25 °C, TB = 75 °C, t1 = 40 min, t2 = < 10 s, 300 cycles, Delta S#!#≤ 10%
Corrosion test
Salt spray test EN 60068-2-52: severity 5, 4 cycles
Continuous current Ia
≤ 200 mA
No load current
≤ 10 mA
Cable material
PUR
Conductor size
0.5 mm²
Cable diameter
Ø 5 mm
Short-circuit protection
Power-up pulse protection
Shock and vibration resistance
Vibration resistance EN 60068-2-6 Fc: 25 g peak (10 Hz ... 2,000 Hz) / –20 °C ... +50 °C#!#Shock resistance EN 60068-2-27 Ea: 100 g 11 ms; 3 shocks in every direction of the 3 coordinate axes / –40 °C ... +85 °C#!#Continuous shock resistance EN 60068-2-29 Eb: 40 g 3 ms rise, 7 ms fall / 5,000 shocks in every direction of the 3 coordinate axes / -20 °C ... +50 °C#!#Broadband noise EN 60068-2-64: 15 g rms (5 Hz ... 2,000 Hz) / 8 hours in every direction of the 3 coordinate axes / –40 °C ... +85 °C
Ambient operating temperature
–40 °C ... +100 °C
Housing material
Stainless steel V4A, DIN 1.4404 / AISI 316L
Sensing face material
Plastic, LCP
Housing length
56 mm
Thread length
46 mm
Tightening torque, max.
Typ. 20 Nm
Protection class
III
UL File No.
E181493
Note
The values are reference values which may vary
Stainless steel (V2A, 304)
Approx. 0.67
Aluminum (Al)
Approx. 0.42
Copper (Cu)
Approx. 0.35
Brass (Br)
Approx. 0.42
Remark
Associated graphic see "Installation"
A
12 mm
B
24 mm
C
12 mm
D
24 mm
E
16 mm
F
64 mm

Specifications may be subject to change without notice