Product Model
IMS30-15BPSNC0S

Selling Points
- 1Rugged Design: Built to withstand harsh environments and severe weather conditions.
- 2Wide Voltage Range: Operates from 7.2 V to 60 V DC, ensuring versatility in various applications.
- 3High Electromagnetic Compatibility: Ensures stable and fault-free processes in electromagnetic-rich environments.
- 4IP68 and IP69K Ratings: Provides excellent protection against dust and water, making it suitable for demanding conditions.
- 5Global Certifications: CE, EAC, CCC, and cULus Listed, ensuring compliance with international standards.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Metric | Housing | Standard design |
Thread size | M30 x 1.5 | Diameter | Ø 30 mm |
Sensing range Sn | 15 mm | Safe sensing range Sa | 12.15 mm |
Installation type | Flush | Switching frequency | 300 Hz |
Connection type | Male connector M12, 4-pin | Switching output | PNP |
Output function | NO | Electrical wiring | DC 3-wire |
Enclosure rating | IP682)#!#IP69K3) | Special features | Resistant to cleaning agents, Temperature resistance |
Special applications | Mobile machines, Hygienic and washdown zones, Difficult application conditions | Items supplied | Mounting nut, brass, nickel-plated (2x) |
Supply voltage | 7.2 V DC ... 60 V DC | Ripple | ≤ 10 % |
Voltage drop | ≤ 2.5 V | Time delay before availability | 100 ms |
Hysteresis | 3 % ... 20 % | Reproducibility | ≤ 2 % |
Temperature drift (of Sr) | ± 10 % | EMC | Emitted interference and interference immunity in accordance with Motor Insurance Directive ECE-R10 Rev. 5: E1-Type approval#!#Interference immunity in accordance with DIN ISO 11452-2: 100 V/m#!#AM vertical 20 MHz - 800 MHz; AM horizontal 200 MHz - 800 MHz; PM vertical/horizontal 800 MHz - 2.7 GHz#!#Conducted disturbances in accordance with ISO 7637-2 (pulse/severity/failure criterion 12 V/failure criterion 24 V): 1/IV/C/C, 2a/IV/A/A, 2b/IV/C/C, 3a/IV/A/A, 3b/IV/A/A, 4/IV/C/A, 5a/IV/B/B, 5b/IV/B/B#!#EN 61000-4-2 ESD: 4 kV CD / 8 kV AD#!#EN 61000-4-3 HF radiated: 10 V/m#!#EN 61000-4-4 burst: 2 kV#!#EN 61000-4-5 surge: 0,5 kV L-to-L, Ri: 2 Ohm |
Environmental test | Quick temperature change EN 60068-2-14, Na: TA = –25 °C, TB = 75 °C, t1 = 40 min, t2 = < 10 s, 300 cycles, Delta S#!#≤ 10% | Corrosion test | Salt spray test EN 60068-2-52: severity 5, 4 cycles |
Continuous current Ia | ≤ 200 mA | No load current | ≤ 10 mA |
Short-circuit protection | ✔ | Power-up pulse protection | ✔ |
Shock and vibration resistance | Vibration resistance EN 60068-2-6 Fc: 25 g peak (10 Hz ... 2,000 Hz) / –20 °C ... +50 °C#!#Shock resistance EN 60068-2-27 Ea: 100 g 11 ms; 3 shocks in every direction of the 3 coordinate axes / –40 °C ... +85 °C#!#Continuous shock resistance EN 60068-2-29 Eb: 40 g 3 ms rise, 7 ms fall / 5,000 shocks in every direction of the 3 coordinate axes / -20 °C ... +50 °C#!#Broadband noise EN 60068-2-64: 15 g rms (5 Hz ... 2,000 Hz) / 8 hours in every direction of the 3 coordinate axes / –40 °C ... +85 °C | Ambient operating temperature | –40 °C ... +100 °C |
Housing material | Stainless steel V4A, DIN 1.4404 / AISI 316L | Sensing face material | Plastic, LCP |
Housing length | 70 mm | Thread length | 52.15 mm |
Tightening torque, max. | Typ. 100 Nm | Protection class | III |
UL File No. | E181493 | Note | The values are reference values which may vary |
Stainless steel (V2A, 304) | Approx. 0.62 | Aluminum (Al) | Approx. 0.26 |
Copper (Cu) | Approx. 0.17 | Brass (Br) | Approx. 0.27 |
Remark | Associated graphic see "Installation" | B | 40 mm |
C | 30 mm | D | 45 mm |
F | 120 mm |
Specifications may be subject to change without notice