Product Model

IMS30-20NNONU2S

In Stock
Last updated: 2025/4/21
sick IMS30-20NNONU2S

Selling Points

  • 1High Sensitivity and Accuracy: Detects metal objects with precision and reliability.
  • 2Non-Flush Installation: Easy to integrate into various industrial settings.
  • 3500 Hz Switching Frequency: Fast and efficient operation for real-time detection.
  • 4Sensing Range of 20 mm: Effective detection within a specified distance.
  • 5Durable Construction: Built to withstand harsh industrial environments.
Product Details
IMS30-20NNONU2S
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Metric
Housing
Standard design
Thread size
M30 x 1.5
Diameter
Ø 30 mm
Sensing range Sn
20 mm
Safe sensing range Sa
16.2 mm
Installation type
Non-flush
Switching frequency
500 Hz
Connection type
Cable, 3-wire, 2 m
Switching output
NPN
Output function
NC
Electrical wiring
DC 3-wire
Enclosure rating
IP681)#!#IP69K2)
Special features
Resistant to cleaning agents, Temperature resistance
Special applications
Mobile machines, Hygienic and washdown zones, Difficult application conditions
Items supplied
Mounting nut, brass, nickel-plated (2x)
Supply voltage
7.2 V DC ... 60 V DC
Ripple
≤ 10 %
Voltage drop
≤ 2.5 V
Time delay before availability
100 ms
Hysteresis
3 % ... 20 %
Reproducibility
≤ 2 %
Temperature drift (of Sr)
± 10 %
EMC
Emitted interference and interference immunity in accordance with Motor Insurance Directive ECE-R10 Rev. 5: E1-Type approval#!#Interference immunity in accordance with DIN ISO 11452-2: 100 V/m#!#AM vertical 20 MHz - 800 MHz; AM horizontal 200 MHz - 800 MHz; PM vertical/horizontal 800 MHz - 2.7 GHz#!#Conducted disturbances in accordance with ISO 7637-2 (pulse/severity/failure criterion 12 V/failure criterion 24 V): 1/IV/C/C, 2a/IV/A/A, 2b/IV/C/C, 3a/IV/A/A, 3b/IV/A/A, 4/IV/C/A, 5a/IV/B/B, 5b/IV/B/B#!#EN 61000-4-2 ESD: 4 kV CD / 8 kV AD#!#EN 61000-4-3 HF radiated: 10 V/m#!#EN 61000-4-4 burst: 2 kV#!#EN 61000-4-5 surge: 0,5 kV L-to-L, Ri: 2 Ohm
Environmental test
Quick temperature change EN 60068-2-14, Na: TA = –25 °C, TB = 75 °C, t1 = 40 min, t2 = < 10 s, 300 cycles, Delta S#!#≤ 10%
Corrosion test
Salt spray test EN 60068-2-52: severity 5, 4 cycles
Continuous current Ia
≤ 200 mA
No load current
≤ 10 mA
Cable material
PUR
Conductor size
0.5 mm²
Cable diameter
Ø 5 mm
Short-circuit protection
Power-up pulse protection
Shock and vibration resistance
Vibration resistance EN 60068-2-6 Fc: 25 g peak (10 Hz ... 2,000 Hz) / –20 °C ... +50 °C#!#Shock resistance EN 60068-2-27 Ea: 100 g 11 ms; 3 shocks in every direction of the 3 coordinate axes / –40 °C ... +85 °C#!#Continuous shock resistance EN 60068-2-29 Eb: 40 g 3 ms rise, 7 ms fall / 5,000 shocks in every direction of the 3 coordinate axes / -20 °C ... +50 °C#!#Broadband noise EN 60068-2-64: 15 g rms (5 Hz ... 2,000 Hz) / 8 hours in every direction of the 3 coordinate axes / –40 °C ... +85 °C
Ambient operating temperature
–40 °C ... +100 °C
Housing material
Stainless steel V4A, DIN 1.4404 / AISI 316L
Sensing face material
Plastic, LCP
Housing length
61 mm
Thread length
43.65 mm
Tightening torque, max.
Typ. 100 Nm
Protection class
III
UL File No.
E181493
Note
The values are reference values which may vary
Stainless steel (V2A, 304)
Approx. 0.78
Aluminum (Al)
Approx. 0.44
Copper (Cu)
Approx. 0.36
Brass (Br)
Approx. 0.46
Remark
Associated graphic see "Installation"
A
20 mm
B
62 mm
C
30 mm
D
60 mm
E
20 mm
F
160 mm

Specifications may be subject to change without notice