Product Model

IQ08-02BPOKR9SS07

In Stock
Last updated: 2025/4/17
sick IQ08-02BPOKR9SS07

Selling Points

  • 1High Accuracy: Detects objects with a sensing range of 2 mm for precise detection.
  • 2Durable Design: Constructed with plastic (VISTAL®) for robustness and resistance to shock and vibrations.
  • 3Flush Installation: Easy to install in flush configurations, suitable for various mounting types.
  • 4Wide Operating Range: Operates between -25°C and +75°C, ensuring reliable performance in diverse environments.
  • 5Advanced Protection: Equipped with reverse polarity protection and short-circuit overload protection for added safety.
Product Details
IQ08-02BPOKR9SS07
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Rectangular
Dimensions (W x H x D)
8 mm x 40 mm x 8 mm
Sensing range Sn
2 mm
Safe sensing range Sa
1.62 mm
Installation type
Flush
Switching frequency
2,000 Hz
Connection type
Cable with connector M8, 3-pin, with knurled nuts, 0.1 m
Switching output
PNP
Output function
NC
Electrical wiring
DC 3-wire
Enclosure rating
IP67, IP68
Special characteristic
With mounting hole
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 10 %
Voltage drop
≤ 2 V
Time delay before availability
≤ 100 ms
Hysteresis
5 % ... 15 %
Reproducibility
≤ 2 %3)#!#4)
Temperature drift (of Sr)
± 10 %
EMC
According to EN 60947-5-2
Continuous current Ia
≤ 200 mA
No load current
10 mA
Cable material
PVC
Short-circuit protection
Power-up pulse protection
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +75 °C
Housing material
Plastic, VISTAL®
Sensing face material
Plastic, VISTAL®
Tightening torque, max.
≤ 1.5 Nm
UL File No.
NRKH.E348498
Note
The values are reference values which may vary
Stainless steel (V2A, 304)
Approx. 0.7
Aluminum (Al)
Approx. 0.3
Copper (Cu)
Approx. 0.2
Brass (Br)
Approx. 0.3
Remark
Associated graphic see "Installation"
A
0 mm
B
10 mm
C
8 mm
D
6 mm
E
0 mm
F
16 mm
G
0 mm

Specifications may be subject to change without notice