Product Model
IQ12-05BPPKW2S

Selling Points
- 1High Sensing Accuracy: Detects objects with a sensing range of 5mm for precise detection.
- 2Compact Design: Rectangular housing with dimensions 12 mm x 40 mm x 26 mm for easy integration.
- 3Flush Installation: Designed for flush installation, ensuring minimal space usage.
- 4IP67 Rating: Durable and resistant to dust and water, suitable for harsh environments.
- 5Reliable Operation: Operates within a wide temperature range (-25°C to 75°C) and up to 2kHz switching frequency.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Rectangular | Dimensions (W x H x D) | 12 mm x 40 mm x 26 mm |
Sensing range Sn | 5 mm | Safe sensing range Sa | 4.05 mm |
Installation type | Flush | Switching frequency | 2,000 Hz |
Connection type | Cable, 4-wire, 2 m | Switching output | PNP |
Output function | Complementary | Electrical wiring | DC 4-wire |
Enclosure rating | IP68 | Special characteristic | Triple sensing range |
Supply voltage | 10 V DC ... 30 V DC | Ripple | ≤ 10 % |
Voltage drop | ≤ 3 V | Time delay before availability | ≤ 100 ms |
Hysteresis | 5 % ... 15 % | Reproducibility | ≤ 2 %3)#!#4) |
Temperature drift (of Sr) | ± 10 % | EMC | According to EN 60947-5-2 |
Continuous current Ia | ≤ 200 mA | No load current | 10 mA |
Cable material | PVC | Conductor size | 0.25 mm² |
Cable diameter | Ø 3.7 mm | Short-circuit protection | ✔ |
Power-up pulse protection | ✔ | Shock and vibration resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
Ambient operating temperature | –25 °C ... +75 °C | Housing material | Plastic, VISTAL® |
Sensing face material | Plastic, VISTAL® | Tightening torque, max. | ≤ 1 Nm |
Note | The values are reference values which may vary | Stainless steel (V2A, 304) | 0.7 |
Aluminum (Al) | 0.4 | Copper (Cu) | 0.3 |
Brass (Br) | 0.4 | Remark | Associated graphic see "Installation" |
A | 0 mm | B | 15 mm |
C | 12 mm | D | 15 mm |
E | 0 mm | F | 40 mm |
G | 0 mm |
Specifications may be subject to change without notice