Product Model
IQ40-20BNOKC0K

Selling Points
- 1Reliable Detection: Detects objects with utmost precision, unaffected by material or temperature changes.
- 2Robust Design: Built with PBT plastic housing, ensuring high resistance to shocks and vibrations.
- 3Easy Installation: Features a push-lock mounting system for quick and tool-free setup.
- 4Wide Operating Range: Operates within a broad ambient temperature range of –25 °C to +85 °C.
- 5High Sensitivity: Offers a sensing range of 20 mm, with a safe sensing range of 16.2 mm.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Housing | Rectangular | Housing | Short-body |
Dimensions (W x H x D) | 40 mm x 40 mm x 66 mm | Sensing range Sn | 20 mm |
Safe sensing range Sa | 16.2 mm | Installation type | Flush |
Switching frequency | 150 Hz | Connection type | Male connector M12, 4-pin |
Switching output | NPN | Output function | NC |
Electrical wiring | DC 3-wire | Enclosure rating | IP67, IP68, IP69K |
Special applications | Difficult application conditions | Items supplied | Push-lock mounting system (1x) |
Supply voltage | 10 V DC ... 30 V DC | Ripple | ≤ 10 V |
Voltage drop | ≤ 2 V | Time delay before availability | ≤ 50 ms |
Hysteresis | 3 % ... 15 % | Reproducibility | ≤ 2 % |
Temperature drift (of Sr) | ± 10 % | Continuous current Ia | ≤ 200 mA |
No load current | 12.5 mA | Short-circuit protection | ✔ |
Power-up pulse protection | ✔ | Shock and vibration resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
Ambient operating temperature | –25 °C ... +85 °C | Ambient temperature, storage | –40 °C ... +85 °C |
Housing material | Plastic, PA 66 | Sensing face material | Plastic, PA 66 |
Tightening torque, max. | 1.8 Nm | Protection class | II |
UL File No. | E348498 | Note | The values are reference values which may vary |
Stainless steel (V2A, 304) | Approx. 0.71 | Aluminum (Al) | Approx. 0.3 |
Copper (Cu) | Approx. 0.25 | Brass (Br) | Approx. 0.36 |
Remark | Associated graphic see "Installation" | A | 0 mm |
B | 40 mm | C | 40 mm |
D | 60 mm | E | 0 mm |
F | 70 mm |
Specifications may be subject to change without notice