Product Model

IQ40-40NPOKK0S

In Stock
Last updated: 2025/4/22
sick IQ40-40NPOKK0S

Selling Points

  • 1Operates reliably in extreme conditions with severe weather.
  • 2Functions from –25 °C to 85 °C, ensuring consistent performance.
  • 3Designed with state-of-the-art ASIC technology for enhanced durability.
  • 4Extremely watertight, suitable for harsh industrial environments.
  • 5Quick and tool-free mounting system for efficient setup.
Product Details
IQ40-40NPOKK0S
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Rectangular
Housing
Standard design
Dimensions (W x H x D)
40 mm x 40 mm x 118 mm
Sensing range Sn
40 mm
Safe sensing range Sa
32.4 mm
Installation type
Non-flush
Switching frequency
100 Hz
Connection type
Cable gland
Switching output
PNP
Output function
NC
Electrical wiring
DC 3-wire
Enclosure rating
IP67, IP68, IP69K
Special applications
Difficult application conditions
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 10 V
Voltage drop
≤ 2 V
Time delay before availability
≤ 50 ms
Hysteresis
3 % ... 15 %
Reproducibility
≤ 6 %
Temperature drift (of Sr)
± 10 %
Continuous current Ia
≤ 200 mA
No load current
12.5 mA
Cable gland clamping area
M20 1.5
Wire size
≤ 2.5 mm²
Short-circuit protection
Power-up pulse protection
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +85 °C
Ambient temperature, storage
–40 °C ... +85 °C
Housing material
Plastic, PA 66
Sensing face material
Plastic, PA 66
Tightening torque, max.
1.8 Nm
Protection class
II
UL File No.
E348498
Note
The values are reference values which may vary
Stainless steel (V2A, 304)
Approx. 0.8
Aluminum (Al)
Approx. 0.34
Copper (Cu)
Approx. 0.27
Brass (Br)
Approx. 0.38
Remark
Associated graphic see "Installation"
A
42 mm
B
150 mm
C
40 mm
D
120 mm
E
40 mm
F
150 mm

Specifications may be subject to change without notice