Product Model

IQC12-04BPPKQ8SA71

In Stock
Last updated: 2025/4/23
sick IQC12-04BPPKQ8SA71

Selling Points

  • 1High-precision detection with advanced sensor technology.
  • 2Robust design for harsh industrial environments.
  • 3Easy integration with existing automation systems.
  • 4Real-time data transmission for efficient monitoring.
  • 5Long-lasting durability with minimal maintenance needs.
Product Details
IQC12-04BPPKQ8SA71
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Rectangular
Dimensions (W x H x D)
12 mm x 40 mm x 26 mm
Sensing range Sn
0 mm ... 4 mm
Safe sensing range Sa
3.24 mm
Number of switching points
Up to 4 adjustable switching points or windows
Switching modes
Single point, Window mode, Two point mode, Visual adjustment indicator
Switching frequency Qint.1 / Qint.2 on Pin2
1,000 Hz
Installation type
Flush
Connection type
Cable with M12 male connector, 4-pin, 0.2 m
Switching output
PNP
Output Q/C
Switching output or IO-Link mode
Output MFC
Switching output or input
Output function
NC / NO
Output characteristic
Programmable
Electrical wiring
DC 4-wire
Enclosure rating
IP68
Special features
Smart Task, IO-Link
Pin 2 configuration
External input, Teach-in, switching signal
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 10 %
Voltage drop
≤ 2 V
Hysteresis
Programmable
Reproducibility
≤ 5 %4)#!#5)
Temperature drift (of Sr)
± 10 %
EMC
According to EN 60947-5-2
Continuous current Ia
≤ 200 mA
No load current
35 mA
Short-circuit protection
Power-up pulse protection
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +75 °C
Housing material
Plastic, VISTAL®
Sensing face material
Plastic, VISTAL®
Tightening torque, max.
< 1 Nm
Teach-in accuracy
+/- 3% of Sr
Resolution, typical (range)
20 μm (0 mm ... 4 mm)
Resolution, maximum (area)
40 μm (0 mm ... 4 mm)
Communication interface
IO-Link V1.1
Communication Interface detail
COM2 (38,4 kBaud)
Cycle time
5 ms
Process data length
32 Bit
Process data structure
Bit 0 = switching signal QL1#!#Bit 1 = switching signal QL2#!#Bit 2 = switching signal QInt3#!#Bit 3 = switching signal QInt4#!#Bit 18 ... 31 = counting value
Factory setting
Switching Point 1: reference value 1#!#Output: normally open#!#Pin 2 configuration: input
Note
Reference value in Digits for switching point in mm stored in the sensor
Reference value 1
4 mm
Reference value 2
3 mm
Reference value 3
2 mm
Reference value 4
1 mm
Stainless steel (V2A, 304)
Approx. 0.7
Aluminum (Al)
Approx. 0.4
Copper (Cu)
Approx. 0.3
Brass (Br)
Approx. 0.4
Remark
Associated graphic see "Installation"
A
0 mm
B
12 mm
C
12 mm
D
12 mm
E
0 mm
F
32 mm
G
0 mm
Smart Task name
Counter + debouncing
Logic function
Window#!#Hysteresis#!#Direct
Timer function
Deactivated#!#Switch-on delay#!#Off delay#!#ON and OFF delay#!#Impulse (one shot)
Inverter
Adjustable
Maximum counting frequency
SIO Logic: 1000 Hz1)#!#IOL: 1000 Hz2)
Counter reset
SIO Logic: 500 µs#!#IOL: ---
Debounce time max.
SIO Logic: 30 s1)#!#IOL: 30 s2)
Switching signal_Switching signal QL1
Output type (dependant on the adjusted threshold)
Switching signal_Switching signal QL2
Output type (dependant on the adjusted threshold)
Measuring value
Counting value

Specifications may be subject to change without notice