Selling Points

  • 1High-precision detection with advanced inductive technology.
  • 2Compact design for easy integration into various industrial applications.
  • 3Robust and reliable performance in harsh environments.
  • 4Easy setup with minimal configuration required.
  • 5Compatible with a wide range of industrial control systems.
Product Details
IQR80-50BPPKC0S
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Housing
Rectangular
Dimensions (W x H x D)
80 mm x 40 mm x 114 mm
Sensing range Sn
50 mm
Safe sensing range Sa
40.5 mm
Installation type
Flush
Switching frequency
250 Hz
Connection type
Male connector M12, 4-pin
Switching output
PNP
Output function
Complementary
Electrical wiring
DC 4-wire
Enclosure rating
IP68
Special features
Reduction factor 1, Weld immune
Special applications
Welding range
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 10 %
Voltage drop
≤ 1.8 V
Hysteresis
3 % ... 15 %
Reproducibility
≤ 2 %
Temperature drift (of Sr)
≤ ± 10 %
Continuous current Ia
≤ 200 mA
No load current
≤ 15 mA
Off-state current
≤ 0.1 mA
Short-circuit protection
Magnetic field strength
≤ 100 mT
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +70 °C
Housing material
Plastic, PBT
Sensing face material
Plastic, PBT
Tightening torque, max.
Typ. 4 Nm
Protection class
II
UL File No.
E191603
Note
The values are reference values which may vary
Reduction factor
Reduction factor 1
Stainless steel (V2A, 304)
1
Aluminum (Al)
1
Copper (Cu)
1
Brass (Br)
1
Remark
Associated graphic see "Installation"
A
40 mm
B
160 mm
C
80 mm
D
150 mm
E
0 mm
F
300 mm
G
0 mm

Specifications may be subject to change without notice