Product Model
UM18-21212D212

Selling Points
- 1High Accuracy: Measures distances with a resolution of ≥ 0.069 mm and a measurement accuracy of ± 1%.
- 2Adjustable Operating Modes: Features adjustable operating modes including switching point (DtO), switching window, and background (ObSB).
- 3Robust Connectivity: Equipped with IO-Link V1.1 for process data, parameterization, diagnosis, and data storage.
- 4Wide Detection Range: Detects objects within a range of 65 mm to 350 mm or 600 mm with precise detection.
- 5Fast Response Time: Responds quickly with a response time of 64 ms, ideal for real-time applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Operating range, limiting range | 65 mm ... 350 mm, 600 mm | Target | Natural objects |
Resolution | ≥ 0.069 mm | Repeatability | ± 0.15 % |
Measurement accuracy | ± 1 % | Temperature compensation | ✔ |
Response time | 64 ms | Switching frequency | 12 Hz |
Output time | 16 ms | Ultrasonic frequency (typical) | 400 kHz |
Additional function | Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, invertible digital output, teach-in of analog output, Invertable analog output, multifunctional input: external teach / synchronization / multiplexing, synchronization of up to 20 sensors, multiplexing: no cross talk of up to 20 sensors, reset to factory default | Safety-related parameters_MTTFD | 101 years |
Safety-related parameters_DCavg | 0% | IO-Link_Function | Process data, parameterization, diagnosis, data storage |
Digital output_Number | 11) | Digital output_Type | Push-pull: PNP/NPN |
Digital output_Maximum output current IA | ≤ 100 mA | Analog output_Number | 1 |
Analog output_Type | Voltage output | Analog output_Voltage | 0 V ... 10 V, ≥ 100,000 Ω |
Analog output_Resolution | 12 bit | Multifunctional input (MF) | 1 x MF |
Hysteresis | 5 mm | Supply voltage UB | DC 10 V ... 30 V |
Power consumption | ≤ 1.2 W | Initialization time | < 300 ms |
Indication | 2 x LED | Enclosure rating | IP65 / IP67 |
Protection class | III | Dimensions (W x H x D) | 18 mm x 18 mm x 68.7 mm |
Design | Cylindrical | Sending axis | Angled |
Housing material | Metal (nickel-plated brass, ultrasonic transducer: polyurethane foam, glass epoxy resin) | Weight | 30 g |
Thread size | M18 x 1 | Connection type | Male connector, M12, 5-pin |
Specifications may be subject to change without notice