Product Model
UM30-212118

Selling Points
- 1Ensures precise measurements with integrated temperature compensation.
- 2Supports sensing ranges up to 8,000 mm, catering to various industrial applications.
- 3Immune to dust, dirt, and fog, ensuring reliable operation in harsh conditions.
- 4Available with combined analog and digital outputs for seamless integration.
- 5Simple setup options and adjustable distance settings for quick installation and configuration.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Operating range, limiting range | 65 mm ... 350 mm, 600 mm | Target | Natural objects |
Resolution | ≥ 0.18 mm | Repeatability | ± 0.15 % |
Measurement accuracy | ± 1 % | Temperature compensation | ✔ |
Response time | 64 ms | Switching frequency | 12 Hz |
Output time | 16 ms | Ultrasonic frequency (typical) | 400 kHz |
Detection area (typical) | See diagrams | Additional function | Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default |
Safety-related parameters_MTTFD | 101 years | Safety-related parameters_DCavg | 0% |
Digital output_Number | 11) | Digital output_Type | PNP |
Digital output_Maximum output current IA | ≤ 200 mA | Analog output_Number | 1 |
Analog output_Type | Current output / voltage output | Analog output_Function | Automatic selection of analog current or voltage output dependent on load |
Analog output_Current | 4 mA ... 20 mA, ≤ 500 Ω2) | Analog output_Voltage | 0 V ... 10 V, ≥ 100,000 Ω |
Analog output_Resolution | 12 bit | Multifunctional input (MF) | 1 x MF |
Hysteresis | 5 mm | Supply voltage UB | DC 9 V ... 30 V |
Power consumption | ≤ 2.4 W | Initialization time | < 300 ms |
Indication | LED display, 2 x LED | Enclosure rating | IP65 / IP67 |
Protection class | III | Dimensions (W x H x D) | 30 mm x 30 mm x 84 mm |
Design | Cylindrical | Sending axis | Straight |
Housing material | Metal (nickel-plated brass, PBT, ultrasonic transducer: polyurethane foam, glass epoxy resin) | Weight | 150 g |
Thread size | M30 x 1.5 | Connection type | Male connector, M12, 5-pin |
Specifications may be subject to change without notice