Product Model

UM30-214118

In Stock
Last updated: 2025/4/17
sick UM30-214118

Selling Points

  • 1High Accuracy: Detects objects like glass, liquids, and transparent foils with ±1% accuracy.
  • 2Flexible Operating Modes: Adjustable operating modes (DtO, Wnd, ObSB) for various detection scenarios.
  • 3Robust Design: IP67 rated, immune to dust, dirt, and fog, ensuring reliable operation in harsh environments.
  • 4Easy Setup: Display enables fast and flexible sensor adjustment before installation.
  • 5Multi-Sensor Capability: Synchronization mode allows up to 10 sensors to work as one large sensor for area detection.
Product Details
UM30-214118
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Operating range, limiting range
350 mm ... 3,400 mm, 5,000 mm
Target
Natural objects
Resolution
≥ 0.18 mm
Repeatability
± 0.15 %
Measurement accuracy
± 1 %
Temperature compensation
Response time
180 ms
Switching frequency
4 Hz
Output time
43 ms
Ultrasonic frequency (typical)
120 kHz
Detection area (typical)
See diagrams
Additional function
Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default
Safety-related parameters_MTTFD
101 years
Safety-related parameters_DCavg
0%
Digital output_Number
11)
Digital output_Type
PNP
Digital output_Maximum output current IA
≤ 200 mA
Analog output_Number
1
Analog output_Type
Current output / voltage output
Analog output_Function
Automatic selection of analog current or voltage output dependent on load
Analog output_Current
4 mA ... 20 mA, ≤ 500 Ω2)
Analog output_Voltage
0 V ... 10 V, ≥ 100,000 Ω
Analog output_Resolution
12 bit
Multifunctional input (MF)
1 x MF
Hysteresis
50 mm
Supply voltage UB
DC 9 V ... 30 V
Power consumption
≤ 2.4 W
Initialization time
< 300 ms
Indication
LED display, 2 x LED
Enclosure rating
IP65 / IP67
Protection class
III
Dimensions (W x H x D)
47.5 mm x 47.5 mm x 102 mm
Design
Cylindrical
Sending axis
Straight
Housing material
Metal (nickel-plated brass, PBT, ultrasonic transducer: polyurethane foam, glass epoxy resin)
Weight
210 g
Thread size
M30 x 1.5
Connection type
Male connector, M12, 5-pin

Specifications may be subject to change without notice