Product Model
WTB250-2R1531

Selling Points
- 1Visible Red Light LED: Simplifies alignment with an easy-to-read positioning indicator for simple commissioning.
- 2Background Suppression: Enhances reliability in difficult ambient light conditions by suppressing background noise.
- 3Flexible Voltage Supply: Compatible with 10-30 V DC or 24-240 V AC/DC voltage supply in a compact design.
- 4Adjustable Sensing Range: Offers a sensing range of 100 mm to 300 mm with a potentiometer for precise adjustment.
- 5IP67 Enclosure Rating: Provides robust protection against dust and water, ensuring reliable operation in harsh environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Functional principle | Photoelectric proximity sensor | Functional principle detail | Background suppression |
Dimensions (W x H x D) | 20 mm x 60 mm x 43.9 mm | Housing design (light emission) | Rectangular |
Sensing range max. | 100 mm ... 300 mm | Sensing range | 100 mm ... 300 mm |
Focus | Approx. 3° | Type of light | Visible red light |
Light source | LED | Light spot size (distance) | Ø 30 mm (300 mm) |
Angle of dispersion | Approx. 3° | Adjustment | Potentiometer, 2 turns#!#Potentiometer, 2 rotations |
Supply voltage UB | 24 V DC ... 240 V DC1)#!#24 V AC/DC ... 240 V AC/DC1) | Power consumption | ≤ 5 VA |
Switching output | Relay, electrically isolated | Output function | Change-over contacts |
Switching mode | Light switching | Switching current (switching voltage) | 3 A (240 V AC)#!#3 A (30 V DC) |
Response time | ≤ 15 ms | Switching frequency | 33 Hz |
Connection type | Cable, 5-wire, 2 m | Cable material | Plastic, PVC |
Conductor cross section | 0.76 mm² | Cable diameter | Ø 6.4 mm |
Circuit protection | A5)#!#C6) | Protection class | II |
Overvoltage category | 2 | Weight | 160 g |
Housing material | Plastic, ABS | Optics material | Plastic, PMMA |
Enclosure rating | IP67 | Items supplied | BEF-W250 mounting bracket |
Electromagnetic compatibility (EMC) | EN 60947-5-2 | Ambient operating temperature | –25 °C ... +55 °C |
Ambient temperature, storage | –40 °C ... +70 °C | UL File No. | NRKH2.E300503 & NRKH8.E300503 |
Specifications may be subject to change without notice