Product Model
AW40K-N04B-12Z-B

Selling Points
- 1Precise pressure regulation with a setting range of 0.02 to 0.2 MPa for consistent performance.
- 2Built-in backflow function (K) to prevent reverse flow and protect your system.
- 3Durable metal bowl (12) ensures long-lasting use in demanding environments.
- 4Includes a relieving-type drain cock (Z) for easy maintenance and left-to-right flow direction.
- 5Comes with a bracket (B) for secure mounting and space-saving installation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Made To Order | Standard | Semi-Standard b | With Drain Cock佾 Relieving Type佾 Flow Direction: Left to Right佾 Name Plate佾 Caution Plate For Bowl佾 And Pressure Gauge In Imperial Units: psi,朻 |
Semi-Standard a | 0.02 to 0.2 MPa Setting佾Metal Bowl | Option c | Without Pressure Gauge佾Without Set Nut (For Panel Mount) |
Option b | Without Auto Drain | Option a | With Bracket |
Port Size | 1/2 | Thread Type | NPT |
With Backflow Function | With Backflow Function | Body Size | Body Size |
Specifications may be subject to change without notice