Product Model

AW60K-N06CG-Z-D

In Stock
Last updated: 2025/4/20
SMC AW60K-N06CG-Z-D

Selling Points

  • 1Equipped with a backflow function (K) to prevent reverse flow and ensure system safety.
  • 23/4 NPT port size (06) for compatibility with standard industrial piping systems.
  • 3Round type pressure gauge (G) with dual scale (MPa/psi) for easy monitoring and adjustment.
  • 4Normally closed (C) drain port design, ensuring no drainage until pressure is applied.
  • 5Polycarbonate bowl for durability and clear visibility of contaminants.
Product Details
AW60K-N06CG-Z-D
SMC

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Made To Order
Standard
Unit
Unit On Product Label:psi,‵F;Pressure Gauge:MPa/psi Dual Scale
Drain Port Option b
Drain Cock Without Barb Fitting (For Φ6 X Φ4 Nylon Tube)
Flow Direction
Flow Direction:Left To Right
Exhaust Mechanism
Relieving Type
Drain Port Option a
With Drain Cock
Bowl
Polycarbonate Bowl
Set Pressure
0.05 To 0.85 Mpa Setting;X406:0.05 To 0.4 MPa Setting
Pressure Gauge/Mounting Option
Round Type Pressure Gauge (With Limit Indicator)
Digital Pressure Switch
Without Digital Pressure Switch
Float Type Auto Drain
N.C.(Normally Closed) Drain Port Is Closed When Pressure Is Not Applied
Bracket
Without Bracket
Port Size
3/4
Pipe Thread Type
NPT
With Backflow Function
With Backflow Function
Body Size
60