Product Model

PFM550-N01L-2-A

In Stock
Last updated: 2025/4/19
SMC PFM550-N01L-2-A

Selling Points

  • 1Analog output (4-20 mA) for precise flow monitoring and control.
  • 2NPT1/8 bore size ensures compatibility with standard piping systems.
  • 3Rated flow range of 1 to 50 L/min for versatile applications.
  • 4Includes a calibration certificate for accurate and reliable performance.
  • 5Comes with an operation manual in both Japanese and English for easy setup.
Product Details
PFM550-N01L-2-A
SMC

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Made To Order
Standard
Option 2
None
Option 1
With Lead Wire With Connector (2m)
Calibration Certificate
With Calibration Certificate
Operation Manual
With Operation Manual (Japanese And English)
Output Specification
Analog Output (4 to 20 mA)
Piping Entry Direction
Bottom
Bore Size
NPT1/8
Flow Adjustment Valve
None
Rated Flow Range (Flow Range)
1 To 50(25)L/min

Specifications may be subject to change without notice