Product Model

PFM711-02-E-MA-WT

In Stock
Last updated: 2025/4/22
SMC PFM711-02-E-MA-WT

Selling Points

  • 1Accurate flow measurement with a range of 2 to 100 L/min.
  • 2Includes a calibration certificate for assured precision.
  • 3Features a 1 PNP output and analog (1 to 5 V) output for versatile connectivity.
  • 4Comes with a 2m lead wire with connector and connector cover for easy installation.
  • 5Panel mount adapter included for convenient mounting without a flow adjustment valve.
Product Details
PFM711-02-E-MA-WT
SMC

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Made To Order
Standard
Option 2
Panel Mount Adapter (For Without Flow Adjustment Valve)
Option 1
With Lead Wire With Connector (2m)+Connector Cover (Silicone rubber)
Calibration Certificate
With Calibration Certificate
Operation Manual
With Operation Manual (Japanese And English)
Remote Sensor Unit
Fixed SI Unit
Output Specification
1 PNP Output + Analog (1 to 5 V)
Piping Entry Direction
Straight
Bore Size
Rc1/4
Flow Adjustment Valve
None
Rated Flow Range (Flow Range)
2 To 100(50)L/min