Product Model
ZL3MN04P-K15MZE-GN-B

Selling Points
- 1High suction flow rate of 300 L/min (ANR) for efficient vacuum generation.
- 224VDC operation with built-in light/surge voltage suppressor for reliable performance.
- 3Includes vacuum pressure detection port for precise monitoring and control.
- 4Push-turn locking lever type manual override for easy operation and safety.
- 5Comes with adapter assembly for bottom mounting, enhancing installation flexibility.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Option | Adapter Assembly For Bottom Mounting (Included) | Lead Wire Specifications | Without Lead Wire With Connector Or Without Pressure Switch For Vacuum |
Remote Sensor Unit | With Unit Switching Function Or Without Pressure Switch For Vacuum | Output Specifications | Without Pressure Switch For Vacuum |
Vacuum Pressure Sensor | With Vacuum Pressure Detection (G) Port (Rc1/8,G1/8,NPT1/8) | Manual Override | Push-turn Locking Lever Type |
With Light Surge Voltage Suppressor | With Light/Surge Voltage Suppressor | Electrical Entry | M Plug Connector With Lead Wire Length 300 mm |
Rated Voltage | 24 VDC | Combination Of Supply Valve And Release Valve | Supply Valve (N.C.),Release Valve (N.C.) |
Exhaust | Port Exhaust (Rc1,G1,NPT1) | Vacuum (2/V) Port Size/Supply (1/P) Port Applicable Tubing O.D. | Vacuum (2/V) Port:2 X NPT1/2 (Branch Specification);Supply (1/P) Port:5/16" (Inch) |
Standard Supply Pressure | 0.35 MPa | Max. Suction Flow Rate | 300 L/min (ANR) |
Specifications may be subject to change without notice