Product Model
ZSE20A-T-M-01-JD-X531

Selling Points
- 1Accurate vacuum measurement with a rated pressure range of 0 to -101 kPa.
- 2Dual PNP open collector outputs and analog voltage output for versatile connectivity.
- 3SI unit specifications ensure compatibility with international standards.
- 4R1/8 piping specification for easy integration into existing systems.
- 5Includes a 2m lead wire with connector and panel mount adapter for convenient installation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Made To Order | Lead Wire With Connector (Terminal Cover) | Option 3 | Operation Manual:﹦;Calibration Certificate:- |
Option 2 | Panel Mount Adapter+Front Protection Cover | Option 1 | Lead Wire With Connector(5-core,2 m Lead Wire) |
Piping Specification | R1/8 | Unit Specifications | SI Unit Only |
Output Specifications | PNP Open Collector 2 Outputs + Analog Voltage Output | Rated Pressure Range | 0 To -101 kPa |
Specifications may be subject to change without notice