Product Model
ZSE20B-T-C4L

Selling Points
- 1Accurate pressure monitoring with a range of 0 to -101 kPa.
- 2Dual PNP open collector outputs for versatile connectivity.
- 3Analog voltage output for precise signal transmission.
- 44mm one-touch fitting for easy and secure installation.
- 5Unit selection function for flexible operation in various applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Made To Order | Standard | Option 3 | Operation Manual:﹦;Calibration Certificate:- |
Option 2 | None | Option 1 | Without Lead Wire |
Piping Specification | One-touch Fitting Φ4 mm (Elbow Type) | Unit Specifications | Unit Selection Function |
Output Specifications | PNP Open Collector 2 Outputs + Analog Voltage Output | Rated Pressure Range | 0 To -101 kPa |
Specifications may be subject to change without notice