Product Model
ZSE20B-Y-01

Selling Points
- 1Accurate vacuum pressure monitoring with a range of 0 to -101 kPa.
- 2PNP open collector outputs with a copy function for versatile connectivity.
- 3R1/8 piping specification ensures easy installation and compatibility.
- 4Unit selection function for flexible measurement unit customization.
- 5Standard design with no additional options, ensuring reliability and simplicity.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Made To Order | Standard | Option 3 | Operation Manual:﹦;Calibration Certificate:- |
Option 2 | None | Option 1 | Without Lead Wire |
Piping Specification | R1/8 | Unit Specifications | Unit Selection Function |
Output Specifications | PNP Open Collector 2 Outputs + Copy Function | Rated Pressure Range | 0 To -101 kPa |
Specifications may be subject to change without notice