wago 2002-1391

Selling Points

  • 1Compact Design: 0.8 mm thickness for minimal real estate on DIN rails.
  • 2High Fire Load: 0.044 MJ fire load ensures robust protection.
  • 3Versatile Use: Suitable for end or intermediate placement in DIN rail installations.
  • 4Gray Color: Durable gray finish for easy identification.
  • 5Ex Rated Compatibility: Compatible with Ex rated TOPJOB S terminal blocks.
Product Details
2002-1391
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
0.8?mm?/ 0.031?inches
Height
59 mm / 2.323 inches
Depth
28.9 mm / 1.138 inches
Mounting type
snap-on type
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.044MJ
Weight
1.5g
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-33
eCl@ss 9.0
27-14-11-33
ETIM 9.0
EC000886
ETIM 8.0
EC000886
ECCN
NO US CLASSIFICATION
PU (SPU)
100?(25)?pcs
Packaging type
box
Country of origin
CN
GTIN
4055143234214
Customs tariff number
8538906000
RoHS Compliance Status
Compliant,No Exemption
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice