Product Model
2002-2731

Selling Points
- 1Designed for hazardous areas with ATEX and IECEx certifications.
- 2Compatible with DIN-rail 35 x 15 and 35 x 7.5, ensuring secure and compact installation.
- 3Easy and secure connection of conductors with a nominal cross-section of 2.5 mm².
- 4Enhances organization and identification of connections with a built-in marker slot.
- 5RoHS compliant and meets various international safety standards, including UL 1059 and CSA 22.2 No 158.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Clamping units | 4 | Total number of potentials | 2 |
Number of levels | 2 | Number of jumper slots | 4 |
Width | 5.2?mm?/ 0.205?inches | Height | 92.5?mm?/ 3.642?inches |
Depth from upper-edge of DIN-rail | 51.7?mm?/ 2.035?inches | Potential Marking | L/L |
Mounting type | DIN-35 rail | Marking level | Center/side marking |
Note (material data) | Information on material specifications can be found here | Color | gray |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Fire load | 0.269MJ |
Weight | 12.9g | Processing temperature | -35 … +85?°C |
Continuous operating temperature | -60 … +105?°C | ETIM 9.0 | EC000897 |
ETIM 8.0 | EC000897 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 50?pcs | Packaging type | Box |
Country of origin | DE | GTIN | 4066966327113 |
Customs tariff number | 85369010000 | RoHS Compliance Status | Compliant,No Exemption |
Ratings per | ATEX: PTB 03 ATEX 1162 U / IECEx: PTB 03.0004U (Ex eb IIC Gb) | Rated voltage (III / 3) | 800V |
Rated impulse voltage (III / 3) | 8kV | Rated current | 24A |
Current at conductor cross-section (max.) mm2 | 28A | Legend (ratings) | (III / 3) ? Overvoltage category III / Pollution degree 3 |
Approvals per | CSA 22.2 No 158 | Rated voltage UL (Use Group B) | 600V |
Rated current UL (Use Group B) | 20A | Rated voltage UL (Use Group C) | 600V |
Rated current UL (Use Group C) | 20A | Rated voltage CSA (Use Group B) | 600V |
Rated current CSA (Use Group B) | 24A | Rated voltage CSA (Use Group C) | 600V |
Rated current CSA (Use Group C) | 24A | Reference hazardous areas | See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications” |
Rated voltage EN (Ex e II) | 550V | Rated current (Ex e II) | 17.5A |
Rated current (Ex e II) with jumper | 17A | Power loss, per pole (potential) | 0.766W |
Rated current I<sub>N</sub> for specified power loss | 24A | Resistance value for specified, current-dependent power loss | 0.001Ω |
Connection technology | Push-in CAGE CLAMP? | Total number of connection points | 2 |
Actuation type | Operating tool | Connectable conductor materials | Copper |
Nominal cross-section | 2.5 mm2 | Solid conductor | 0.25 … 4?mm2?/ 22 … 12?AWG |
Solid conductor; push-in termination | 0.75 … 4?mm2?/ 18 … 12?AWG | Fine-stranded conductor | 0.25 … 4?mm2?/ 22 … 12?AWG |
Fine-stranded conductor; with insulated ferrule | 0.25 … 2.5?mm2?/ 22 … 14?AWG | Fine-stranded conductor; with ferrule; push-in termination | 1 … 2.5?mm2?/ 18 … 14?AWG |
Note (conductor cross-section) | Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. | Strip length | 10 … 12?mm?/ 0.39 … 0.47?inches |
Wiring direction | Front-entry wiring | Number of connection points 2 | 2 |
Specifications may be subject to change without notice