Product Model
2002-405

Selling Points
- 1Insulated Push-In Connector for Reliable Connections
- 2Compatible with 2002, 2003, 2006, and 2016 Rail-Mounted Terminal Blocks
- 3Rated Current: 25A for High-Performance Applications
- 4Light Gray Housing for Easy Identification
- 5Compact Dimensions: 0.748 in H x 0.957 in W x 0.161 in D
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 24.3?mm?/ 0.957?inches | Height | 4.1?mm?/ 0.161?inches |
Depth | 19?mm?/ 0.748?inches | Jumper assignment | 1-2-3-4-5 |
Note (material data) | Information on material specifications can be found here | Color | light gray |
Fire load | 0.017MJ | Weight | 2.4g |
Product Group | 22 (TOPJOB S) | eCl@ss 10.0 | 27-14-11-40 |
eCl@ss 9.0 | 27-14-11-40 | ETIM 9.0 | EC000489 |
ETIM 8.0 | EC000489 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 25?pcs | Packaging type | bag |
Country of origin | DE | GTIN | 4055143687393 |
Customs tariff number | 8536698000 | RoHS Compliance Status | Compliant,No Exemption |
Rated voltage (III / 3) | 800V | Rated current | 25A |
Rated current (Ex e II) | 20A | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice