Product Model
2002-611

Selling Points
- 1Secure and efficient connection method.
- 2Handles high electrical demands with reliability.
- 3Easy access for conductor insertion and removal.
- 4Durable and visually distinct design.
- 5High-quality material for long-lasting performance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | According to EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load. | Clamping units | 1 |
Total number of potentials | 1 | Width | 5.2?mm?/ 0.205?inches |
Height | 34.6?mm?/ 1.362?inches | Depth | 19.5?mm?/ 0.768?inches |
Module width | 5.2?mm?/ 0.205?inches | Marking level | Center marking |
Note (material data) | Information on material specifications can be found here | Color | gray |
Insulation material (main housing) | Polyamide (PA66) | Flammability class per UL94 | V0 |
Fire load | 0.032MJ | Weight | 1.9g |
Product Group | 22 (TOPJOB S) | eCl@ss 10.0 | 27-44-03-13 |
eCl@ss 9.0 | 27-14-11-92 | ETIM 9.0 | EC002255 |
ETIM 8.0 | EC002255 | ECCN | NO US CLASSIFICATION |
PU (SPU) | 100?(25)?pcs | Packaging type | box |
Country of origin | DE | GTIN | 4045454997403 |
Customs tariff number | 8536904000 | RoHS Compliance Status | Compliant,No Exemption |
Rated voltage (III / 3) | 500V | Rated impulse voltage (III / 3) | 6kV |
Rated current | 18A | Legend (ratings) | (III / 3) ? Overvoltage category III / Pollution degree 3 |
Connection technology | Push-in CAGE CLAMP? | Actuation type | Operating tool |
Connectable conductor materials | Copper | Nominal cross-section | 2.5 mm2 |
Solid conductor | 0.25 … 4?mm2?/ 22 … 12?AWG | Solid conductor; push-in termination | 0.75 … 4?mm2?/ 18 … 12?AWG |
Fine-stranded conductor | 0.25 … 4?mm2?/ 22 … 12?AWG | Fine-stranded conductor; with insulated ferrule | 0.25 … 2.5?mm2?/ 22 … 14?AWG |
Fine-stranded conductor; with ferrule; push-in termination | 1 … 2.5?mm2?/ 18 … 14?AWG | Note (conductor cross-section) | Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. |
Strip length | 10 … 12?mm?/ 0.39 … 0.47?inches | Number of poles | 1 |
Wiring direction | Front-entry wiring | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice