wago 2004-408

Selling Points

  • 1Insulated Push-In Type: Easy to install with a simple push-in mechanism.
  • 28-Way Configuration: Ideal for connecting multiple conductors in a single terminal block.
  • 3Nominal Current 32 A: Supports high current applications with a rated current of 32 A.
  • 4Light Gray Color: Durable and visually distinct for easy identification.
  • 5RoHS Compliant: Meets environmental standards for safe and sustainable use.
Product Details
2004-408
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
47.6?mm?/ 1.874?inches
Height
4.1?mm?/ 0.161?inches
Depth
19?mm?/ 0.748?inches
Jumper assignment
1-2-3-4-5-6-7-8
Note (material data)
Information on material specifications can be found here
Color
light gray
Fire load
0.03MJ
Weight
6.1g
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-40
eCl@ss 9.0
27-14-11-40
ETIM 9.0
EC000489
ETIM 8.0
EC000489
ECCN
NO US CLASSIFICATION
PU (SPU)
25?pcs
Packaging type
bag
Country of origin
DE
GTIN
4017332070188
Customs tariff number
8536698000
RoHS Compliance Status
Compliant,No Exemption
Rated voltage (III / 3)
800V
Rated current
32A
Rated current (Ex e II)
30A
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice