wago 2006-433

Selling Points

  • 1The WAGO 2006-433 terminal block features CAGE CLAMP® technology, ensuring secure connections without wire damage.
  • 2Suitable for various automation systems and industrial applications, including Ex i and Ex e II environments.
  • 3Rated for 800 V/8 kV, making it ideal for high-voltage applications.
  • 4No special wire preparation required, such as crimps or ferrules, for quick and efficient installation.
  • 5Built with durable materials to withstand shock, vibration, and high temperatures.
Product Details
2006-433
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
20.2?mm?/ 0.795?inches
Height
4.1?mm?/ 0.161?inches
Depth
19?mm?/ 0.748?inches
Jumper assignment
1-3
Design
spanning
Note (material data)
Information on material specifications can be found here
Color
light gray
Fire load
0.011MJ
Weight
2.5g
Product Group
22 (TOPJOB S)
eCl@ss 10.0
27-14-11-40
eCl@ss 9.0
27-14-11-40
ETIM 9.0
EC000489
ETIM 8.0
EC000489
ECCN
NO US CLASSIFICATION
PU (SPU)
25?pcs
Packaging type
bag
Country of origin
DE
GTIN
4017332072274
Customs tariff number
8536698000
RoHS Compliance Status
Compliant,No Exemption
Rated voltage (III / 3)
800V
Rated current
41A
Rated current (Ex e II)
33A
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed