Product Model

2020-210/125-000

In Stock
Last updated: 2025/4/19
wago 2020-210/125-000

Selling Points

  • 12-conductor female connector with push-in CAGE CLAMP technology.
  • 2Pin spacing of 3.5 mm and 10-pole configuration.
  • 3Suitable for conductors up to 1.5 mm² and #16 AWG.
  • 4Centered locking levers ensure secure connections.
  • 5Crafted from durable Polyamide (PA) 66 material.
Product Details
2020-210/125-000
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
According to EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.
Safety information 2
Notice: An appropriate end plate must be applied to the carrier terminal blocks after each female plug.
Clamping units
20
Total number of potentials
10
Width
35.7?mm?/ 1.406?inches
Height
48.9?mm?/ 1.925?inches
Depth
29.8?mm?/ 1.173?inches
Module width
3.5?mm?/ 0.138?inches
Variable coding
Yes
Marking level
Side marking
Anti-rotation protection
Yes
Contact type (pluggable connector)
Female connector/socket
Connector (connection type)
for conductor
Mismating protection
No
Plugging without loss of pin spacing
No
Locking of plug-in connection
Locking lever
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.528MJ
Weight
29.3g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
Product Group
18 (X-COM-System)
eCl@ss 10.0
27-14-11-06
eCl@ss 9.0
27-14-11-06
ETIM 9.0
EC001284
ETIM 8.0
EC001284
ECCN
NO US CLASSIFICATION
PU (SPU)
25?pcs
Packaging type
Box
Country of origin
DE
GTIN
4050821222163
Customs tariff number
8536694040
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 61984
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated current
13.5A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group C)
300V
Rated current UL (Use Group C)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group C)
300V
Rated current CSA (Use Group C)
10A
Rated voltage CSA (Use Group D)
300V
Rated current CSA (Use Group D)
10A
Connection technology
Push-in CAGE CLAMP?
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
1 mm2
Solid conductor
0.14 … 1.5?mm2?/ 24 … 16?AWG
Solid conductor; push-in termination
0.5 … 1.5?mm2?/ 20 … 16?AWG
Fine-stranded conductor
0.14 … 1.5?mm2?/ 24 … 16?AWG
Fine-stranded conductor; with insulated ferrule
0.14 … 0.75?mm2?/ 24 … 18?AWG
Fine-stranded conductor; with ferrule; push-in termination
0.5 … 0.75?mm2?/ 20 … 18?AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
9 … 11?mm?/ 0.35 … 0.43?inches
Number of poles
10
Wiring direction
Front-entry wiring

Specifications may be subject to change without notice