wago 2020-2232

Selling Points

  • 1Supports up to 800 V and 10 A.
  • 2Accommodates conductors from 0.14 to 1.5 mm².
  • 3Easy and secure connection with "s" and "insulated ferrule" options.
  • 4Terminal block width is 3.5 mm, ideal for space-efficient installations.
  • 5Meets requirements for explosive environments, ensuring safety and reliability.
Product Details
2020-2232
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
A separator plate (Item No. 209-191) or a 10 mm end stop (Item No. 249-117) must be placed at the end of a WAGO X-COM?-SYSTEM terminal strip.
Clamping units
2
Female plug slots
2
Total number of potentials
2
Number of levels
2
Number of jumper slots
4
Width
3.5?mm?/ 0.138?inches
Height
80.1?mm?/ 3.154?inches
Depth from upper-edge of DIN-rail
61.4?mm?/ 2.417?inches
Potential Marking
N/L
Design
horizontal type
Mounting type
DIN-35 rail
Marking level
Side marking
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.211MJ
Weight
8.8g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
Product Group
18 (X-COM-System)
eCl@ss 10.0
27-14-11-20
eCl@ss 9.0
27-14-11-20
ETIM 9.0
EC000897
ETIM 8.0
EC000897
ECCN
NO US CLASSIFICATION
PU (SPU)
50?pcs
Packaging type
Box
Country of origin
CN
GTIN
4050821049586
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 60947-7-1
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated current
13.5A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group C)
300V
Rated current UL (Use Group C)
15A
Rated voltage UL (Use Group D)
300V
Rated current UL (Use Group D)
15A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group C)
300V
Rated current CSA (Use Group C)
10A
Power loss, per pole (potential)
0.434W
Rated current I<sub>N</sub> for specified power loss
13.5A
Resistance value for specified, current-dependent power loss
0.002Ω
Connection technology
Push-in CAGE CLAMP?
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
1 mm2
Solid conductor
0.14 … 1.5?mm2?/ 24 … 16?AWG
Solid conductor; push-in termination
0.5 … 1.5?mm2?/ 20 … 16?AWG
Fine-stranded conductor
0.14 … 1.5?mm2?/ 24 … 16?AWG
Fine-stranded conductor; with insulated ferrule
0.14 … 0.75?mm2?/ 24 … 18?AWG
Fine-stranded conductor; with ferrule; push-in termination
0.5 … 0.75?mm2?/ 20 … 18?AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
9 … 11?mm?/ 0.35 … 0.43?inches
Wiring direction
Front-entry wiring

Specifications may be subject to change without notice