Product Model

2022-107/000-006

In Stock
Last updated: 2025/4/19
wago 2022-107/000-006

Selling Points

  • 1High-quality connector: Designed according to EN 61984 standards for reliable connections.
  • 2Versatile usage: Supports nominal voltage of 690V and rated impulse voltage of 6kV.
  • 3Durable material: Made from blue Polyamide (PA66) with UL94 V0 flammability classification.
  • 4Efficient connection: Utilizes Push-in CAGE CLAMP technology for easy conductor connection.
  • 5Compliant with regulations: Meets UL 1059 and CSA 22.2 No 158 standards for industrial applications.
Product Details
2022-107/000-006
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Safety information
According to EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.
Clamping units
7
Total number of potentials
7
Width
36.4?mm?/ 1.433?inches
Height
40.5?mm?/ 1.594?inches
Depth
22.4?mm?/ 0.882?inches
Module width
5.2?mm?/ 0.205?inches
Variable coding
Yes
Marking level
Side marking
Anti-rotation protection
Yes
Contact type (pluggable connector)
Female connector/socket
Connector (connection type)
for conductor
Mismating protection
No
Plugging without loss of pin spacing
Yes
Note (material data)
Information on material specifications can be found here
Color
blue
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.378MJ
Weight
23.1g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
Product Group
18 (X-COM-System)
eCl@ss 10.0
27-14-11-06
eCl@ss 9.0
27-14-11-06
ETIM 9.0
EC001284
ETIM 8.0
EC001284
ECCN
NO US CLASSIFICATION
PU (SPU)
50?pcs
Packaging type
Box
Country of origin
DE
GTIN
4045454705473
Customs tariff number
8536694040
RoHS Compliance Status
Compliant,No Exemption
Ratings per
IEC/EN 61984
Rated voltage (III / 3)
690V
Rated impulse voltage (III / 3)
6kV
Rated current
24A
Current at conductor cross-section (max.) mm2
32A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
600V
Rated current UL (Use Group B)
20A
Rated voltage UL (Use Group C)
600V
Rated current UL (Use Group C)
20A
Rated voltage CSA (Use Group C)
600V
Rated current CSA (Use Group C)
20A
Connection technology
Push-in CAGE CLAMP?
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
2.5 mm2
Solid conductor
0.25 … 4?mm2?/ 22 … 12?AWG
Solid conductor; push-in termination
0.75 … 4?mm2?/ 18 … 12?AWG
Fine-stranded conductor
0.25 … 4?mm2?/ 22 … 12?AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5?mm2?/ 22 … 14?AWG
Fine-stranded conductor; with ferrule; push-in termination
1 … 2.5?mm2?/ 18 … 14?AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
10 … 12?mm?/ 0.39 … 0.47?inches
Number of poles
7
Wiring direction
Front-entry wiring
Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment
DIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests
DIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation location
Service life test, Category?1, Class?A/B
Function test with noise-like vibration
Test passed according to Section 8 of the standard
Frequency
f1= 5 Hz to f2= 150 Hz
Acceleration
5g (highest test level used for all axes)
Test duration per axis
5 h
Test directions
X, Y and Z axes
Monitoring for contact faults/interruptions
Passed
Voltage drop measurement before and after each axis
Passed
Simulated service life test through increased levels of noise-like vibration
Test passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptions
Passed
Extended test scope: Voltage drop measurement before and after each axis
Passed
Shock test
Test passed according to Section 10 of the standard
Shock form
Half sine
Shock duration
30 ms
Number of shocks per axis
3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipment
Passed

Specifications may be subject to change without notice