wago 2250-1201

Selling Points

  • 1500V for reliable high-voltage applications.
  • 21.343 in H x 0.138 in W x 1.098 in D dimensions for space-saving installations.
  • 3Made from polyamide 6.6 for long-lasting performance in various environments.
  • 4Push-in wire connections simplify the installation process.
  • 5Supports wire sizes from 24 to 16 AWG for flexible use in different applications.
Product Details
2250-1201
wago

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Clamping units
2
Total number of potentials
1
Number of levels
1
Number of jumper slots
1
Width
3.5?mm?/ 0.138?inches
Height
34.1?mm?/ 1.343?inches
Depth from upper-edge of DIN-rail
27.9?mm?/ 1.098?inches
Mounting type
DIN-15 rail
Marking level
Center/side marking
Note (material data)
Information on material specifications can be found here
Color
gray
Material group
I
Insulation material (main housing)
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.064MJ
Weight
2.5g
Processing temperature
-35 … +85?°C
Continuous operating temperature
-60 … +105?°C
ETIM 9.0
EC000897
ETIM 8.0
EC000897
ECCN
NO US CLASSIFICATION
PU (SPU)
100?pcs
Packaging type
box
Country of origin
IN
GTIN
4055143965200
Customs tariff number
8536904000
RoHS Compliance Status
Compliant,No Exemption
Ratings per
ATEX: PTB 19 ATEX 1019 U / IECEx: PTB 19.0050U (Ex eb IIC Gb)
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated current
13.5A
Current at conductor cross-section (max.) mm2
17.5A
Legend (ratings)
(III / 3) ? Overvoltage category III / Pollution degree 3
Approvals per
CSA 22.2 No 158
Rated voltage UL (Use Group B)
300V
Rated current UL (Use Group B)
10A
Rated voltage UL (Use Group C)
300V
Rated current UL (Use Group C)
10A
Rated voltage CSA (Use Group B)
300V
Rated current CSA (Use Group B)
10A
Rated voltage CSA (Use Group C)
300V
Rated current CSA (Use Group C)
10A
Reference hazardous areas
See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
Rated voltage EN (Ex e II)
352V
Rated current (Ex e II)
13.5A
Rated current (Ex e II) with jumper
12A
Rated current I<sub>N</sub> for specified power loss
13.5A
Resistance value for specified, current-dependent power loss
0.002Ω
Connection technology
Push-in CAGE CLAMP?
Actuation type
Push-button
Connectable conductor materials
Copper
Nominal cross-section
1 mm2
Solid conductor
0.14 … 1.5?mm2?/ 24 … 16?AWG
Solid conductor; push-in termination
0.5 … 1.5?mm2?/ 20 … 16?AWG
Fine-stranded conductor
0.14 … 1.5?mm2?/ 24 … 16?AWG
Fine-stranded conductor; with insulated ferrule
0.14 … 1 mm2 / 24 … 18 AWG
Fine-stranded conductor; with uninsulated ferrule
0.14 … 1 mm2 / 24 … 18 AWG
Fine-stranded conductor; with ferrule; push-in termination
0.5 … 1 mm2 / 20 … 18 AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
9 … 11?mm?/ 0.35 … 0.43?inches
Wiring direction
Front-entry wiring

Specifications may be subject to change without notice